Evaluation of the performance, operability, and safety of Plasauto μ, a new type of machine for cell‐free and concentrated ascites reinfusion therapy, in a postmarketing clinical study. Issue 4 (19th May 2021)
- Record Type:
- Journal Article
- Title:
- Evaluation of the performance, operability, and safety of Plasauto μ, a new type of machine for cell‐free and concentrated ascites reinfusion therapy, in a postmarketing clinical study. Issue 4 (19th May 2021)
- Main Title:
- Evaluation of the performance, operability, and safety of Plasauto μ, a new type of machine for cell‐free and concentrated ascites reinfusion therapy, in a postmarketing clinical study
- Authors:
- Hasegawa, Midori
Matsushita, Hiromichi
Yahata, Kensei
Sugawara, Akira
Ishibashi, Yoshitaka
Kawahara, Ryoko
Hamasaki, Yoshifumi
Kanno, Hitoshi
Yamada, Sachie
Nii, Norio
Kato, Masao
Ohashi, Atsushi
Koide, Shigehisa
Hayashi, Hiroki
Yuzawa, Yukio
Tsuboi, Naotake - Abstract:
- Abstract: Cell‐free and concentrated ascites reinfusion therapy (CART) is performed by collecting the ascites from the patient, followed by filtration and concentration. Thereafter, concentrated cell‐free ascites is reinfused into the patient intravenously. The new type of machine, Plasauto μ, for managing the process of CART was launched onto the market. We have evaluated the machine through postmarketing clinical study in 17 patients with malignant ascites. The amounts of original and concentrated ascites were 3673 ± 1920 g and 439 ± 228 g, respectively. Recovery rates were acceptable regarding values of total protein, albumin, and IgG that were 55.6% ± 17.3%, 60.2% ± 20.8%, and 58.2% ± 20.5%, respectively. Recovery rates were positively associated with amounts of original ascites and negatively associated with total protein concentration. No adverse events related to the machine were observed. The new type of machine showed preferable performance in processing malignant ascites.
- Is Part Of:
- Therapeutic apheresis and dialysis. Volume 25:Issue 4(2021)
- Journal:
- Therapeutic apheresis and dialysis
- Issue:
- Volume 25:Issue 4(2021)
- Issue Display:
- Volume 25, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2021-0025-0004-0000
- Page Start:
- 407
- Page End:
- 414
- Publication Date:
- 2021-05-19
- Subjects:
- a new type of machine -- ascites -- cell‐free and concentrated ascites reinfusion therapy -- post‐marketing clinical study -- recovery rate
Hemapheresis -- Periodicals
Dialysis -- Periodicals
Blood Component Removal -- Periodicals
Renal Dialysis -- Periodicals
Hémaphérèse -- Périodiques
Dialyse -- Périodiques
Sang -- Collecte et conservation -- Périodiques
616 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1744-9979;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1744-9987 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=tap ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/rd.asp?code=TAP&goto=journal ↗ - DOI:
- 10.1111/1744-9987.13658 ↗
- Languages:
- English
- ISSNs:
- 1744-9979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.642670
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17443.xml