Behavior of AV synchrony pacing mode in a leadless pacemaker during variable AV conduction and arrhythmias. (20th May 2021)
- Record Type:
- Journal Article
- Title:
- Behavior of AV synchrony pacing mode in a leadless pacemaker during variable AV conduction and arrhythmias. (20th May 2021)
- Main Title:
- Behavior of AV synchrony pacing mode in a leadless pacemaker during variable AV conduction and arrhythmias
- Authors:
- Garweg, Christophe
Khelae, Surinder Kaur
Chan, Joseph Yat Sun
Chinitz, Larry
Ritter, Philippe
Johansen, Jens Brock
Sagi, Venkata
Epstein, Laurence M.
Piccini, Jonathan P.
Pascual, Mario
Mont, Lluis
Willems, Rik
Splett, Vincent
Stromberg, Kurt
Sheldon, Todd
Kristiansen, Nina
Steinwender, Clemens - Abstract:
- Abstract: Introduction: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio‐ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study. Methods: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode‐switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)‐40 depending upon AVC status. Results: Forty‐two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI‐40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing. Conclusion: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AVAbstract: Introduction: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio‐ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study. Methods: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode‐switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)‐40 depending upon AVC status. Results: Forty‐two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI‐40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing. Conclusion: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AV block. No pacing safety issues were observed during arrhythmias. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 7(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 7(2021)
- Issue Display:
- Volume 32, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2021-0032-0007-0000
- Page Start:
- 1947
- Page End:
- 1957
- Publication Date:
- 2021-05-20
- Subjects:
- arrhythmias -- atrial fibrillation -- AV synchrony -- leadless pacing -- paroxysmal AV block
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15061 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17444.xml