Accogli, Michele - Abstract:
- ABSTRACT: Background: Leadless pacemaker (L-PM) have been developed in order to overcome the lead- and pocket-related complications associated with transvenous pacemaker (T-PM). The impact of L-PM implantation on the utilization of medical resources, patient comfort and therapy acceptance could differ from that of T-PM. Research design and methods: Prospective, single-center study enrolling 243 consecutive patients undergoing PM implantation. Propensity matching for baseline characteristics yielded 77 matched pairs. Procedural data, patient acceptance (assessed by Florida Patient Acceptance Survey, FPAS) and quality of life (QoL) (assessed at the baseline, 1 week, 3 and 6 months) were compared between the two groups (L-PM and T-PM). Results: The implantation procedure was longer in L-PM than T-PM patients (42.2±16.3 vs. 28.9±11.9 minutes; p<0.001). L-PM was associated with lower intra- and post-operative pain intensity (all p<0.05), shorter hospitalization (3.2±0.5 vs. 3.5±1.1 days; p=0.034), greater patient acceptance (FPAS score: 58.7±7.1 vs. 40.5±4.1; p<0.001), and better QoL on both physical and mental health scales (all p<0.05). Conclusions: Although L-PM implantation takes longer than T-PM, it is better tolerated and accepted by patients and is associated with a better QoL.
- Is Part Of:
- Expert review of medical devices. Volume 18:Number 5(2021)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 18:Number 5(2021)
- Issue Display:
- Volume 18, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 18
- Issue:
- 5
- Issue Sort Value:
- 2021-0018-0005-0000
- Page Start:
- 483
- Page End:
- 491
- Publication Date:
- 2021-05-04
- Subjects:
- Leadless -- pacemaker -- quality of life -- transvenous
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2021.1921573 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 17416.xml