A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks. Issue 25 (11th June 2021)
- Record Type:
- Journal Article
- Title:
- A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks. Issue 25 (11th June 2021)
- Main Title:
- A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks
- Authors:
- Janmee, Nopparat
Preechakasedkit, Pattarachaya
Rodthongkum, Nadnudda
Chailapakul, Orawon
Potiyaraj, Pranut
Ruecha, Nipapan - Abstract:
- Abstract : A novel designed device of CuO-IL/rGO-modified SPCE combined with NaOH-coated wax-printed paper was developed as a non-enzymatic glucose sensor with single-step sample loading in human urine and electrolyte drinks via portable potentiostat. Abstract : A non-enzymatic disposable electrochemical sensor coupled with an automated sample pretreatment paper-based device was developed to avoid an additional sample preparation step for glucose determination in human urine and electrolyte drinks. The automated sample pretreatment paper-based device was successfully fabricated by the simple coating of a strong alkaline solution on a patterned wax paper, and then attached on an electrochemical sensor. The nanocomposite of copper oxide nanoparticles, ionic liquid and reduced graphene oxide (CuO-IL/rGO) modified on the screen-printed carbon electrode (SPCE) was created and used as a non-enzymatic electrochemical glucose sensor. The presence of the CuO-IL/rGO nanocomposite on the screen-printed electrode surface was confirmed by transmission electron microscopy (TEM), scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). Under optimal conditions, glucose was measured by dropping 100 μL sample solution on the device and detected via chronoamperometry (CA) using a smartphone potentiostat controlled by Android app., providing a rapid current response within 20 s and linearity in a range of 0.03–7.0 mM with aAbstract : A novel designed device of CuO-IL/rGO-modified SPCE combined with NaOH-coated wax-printed paper was developed as a non-enzymatic glucose sensor with single-step sample loading in human urine and electrolyte drinks via portable potentiostat. Abstract : A non-enzymatic disposable electrochemical sensor coupled with an automated sample pretreatment paper-based device was developed to avoid an additional sample preparation step for glucose determination in human urine and electrolyte drinks. The automated sample pretreatment paper-based device was successfully fabricated by the simple coating of a strong alkaline solution on a patterned wax paper, and then attached on an electrochemical sensor. The nanocomposite of copper oxide nanoparticles, ionic liquid and reduced graphene oxide (CuO-IL/rGO) modified on the screen-printed carbon electrode (SPCE) was created and used as a non-enzymatic electrochemical glucose sensor. The presence of the CuO-IL/rGO nanocomposite on the screen-printed electrode surface was confirmed by transmission electron microscopy (TEM), scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). Under optimal conditions, glucose was measured by dropping 100 μL sample solution on the device and detected via chronoamperometry (CA) using a smartphone potentiostat controlled by Android app., providing a rapid current response within 20 s and linearity in a range of 0.03–7.0 mM with a limit of detection (LOD) of 0.14 μM. Furthermore, this developed device was successfully applied for determining glucose levels in human urine and electrolyte drinks, exporting satisfying results correlated with a commercial enzymatic glucose biosensor and labeled values of the commercial products. Therefore, this device could be an alternative device for a non-enzymatic glucose sensor with single-step sample loading, allowing for real-time analysis, low cost, portability, disposability, and on-field measurement. … (more)
- Is Part Of:
- Analytical methods. Volume 13:Issue 25(2021)
- Journal:
- Analytical methods
- Issue:
- Volume 13:Issue 25(2021)
- Issue Display:
- Volume 13, Issue 25 (2021)
- Year:
- 2021
- Volume:
- 13
- Issue:
- 25
- Issue Sort Value:
- 2021-0013-0025-0000
- Page Start:
- 2796
- Page End:
- 2803
- Publication Date:
- 2021-06-11
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1ay00676b ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17434.xml