Press-fit reverse shoulder arthroplasty in case of advanced humeral bone loss – Is additional distal fixation necessary for primary stability?. (February 2021)
- Record Type:
- Journal Article
- Title:
- Press-fit reverse shoulder arthroplasty in case of advanced humeral bone loss – Is additional distal fixation necessary for primary stability?. (February 2021)
- Main Title:
- Press-fit reverse shoulder arthroplasty in case of advanced humeral bone loss – Is additional distal fixation necessary for primary stability?
- Authors:
- Jahnke, Alexander
Müller, Felizia
Fonseca Ulloa, Carlos A.
Rickert, Markus
Werner, Birgit S.
Gohlke, Frank - Abstract:
- Abstract: Background: Revision reverse shoulder arthroplasty (RSA) poses considerable surgical challenges. We hypothesized that a newly developed press-fit stem, which is modeled on the medullary canal of the supracondylar region of the distal humerus by a slight distal bend, achieve both correct fit and sufficient primary stability and that additional distal fixation by interlocking screws is favorable in case of advanced humeral bone loss. Methods: A modular tapered press-fit stem was implanted in 16 Sawbone humeri in three consecutively created defect situations (200 mm (experimental group type 3°), 160 mm (type 4°) and 120 mm (type 5°) bone length above the epicondylar line. In experimental groups type 4° and 5°, additional distal interlocking screw fixation with one to three screws was tested. Primary stability was investigated by measuring micromotions with a high-precision rotational setup. Findings: Highest relative micromotions were noted at the proximal end in experimental groups type 3° and type 4°, whereas in type 5° highest micromotions could be seen at the distal end. Overall micromotions were significantly lower in type 3° and increased with extended defect size. In experimental group type 5°, micromotions increased with reduced additional distal screw fixation. Interpretation: The examined press-fit stem did not provide sufficient primary rotational stability in all constructs without additional support. Advanced distal humeral bone loss had a strong impactAbstract: Background: Revision reverse shoulder arthroplasty (RSA) poses considerable surgical challenges. We hypothesized that a newly developed press-fit stem, which is modeled on the medullary canal of the supracondylar region of the distal humerus by a slight distal bend, achieve both correct fit and sufficient primary stability and that additional distal fixation by interlocking screws is favorable in case of advanced humeral bone loss. Methods: A modular tapered press-fit stem was implanted in 16 Sawbone humeri in three consecutively created defect situations (200 mm (experimental group type 3°), 160 mm (type 4°) and 120 mm (type 5°) bone length above the epicondylar line. In experimental groups type 4° and 5°, additional distal interlocking screw fixation with one to three screws was tested. Primary stability was investigated by measuring micromotions with a high-precision rotational setup. Findings: Highest relative micromotions were noted at the proximal end in experimental groups type 3° and type 4°, whereas in type 5° highest micromotions could be seen at the distal end. Overall micromotions were significantly lower in type 3° and increased with extended defect size. In experimental group type 5°, micromotions increased with reduced additional distal screw fixation. Interpretation: The examined press-fit stem did not provide sufficient primary rotational stability in all constructs without additional support. Advanced distal humeral bone loss had a strong impact on primary fixation. In experimental group type 5° with 120 mm bone remaining, it might be beneficial to use three distal interlocking screws in the supracondylar region in order to neutralize torque and to avoid early loosening. Highlights: Revision reverse shoulder arthroplasty poses surgical challenges. Distal interlocking screws are favorable in case of advanced humeral bone loss. Three defect situations (types 3°, 4° and 5°) were analyzed. Micromotions were lower in type 3° and increased with extended defect size. It might be beneficial to use at least two screws with type 5° defect. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 82(2021)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 82(2021)
- Issue Display:
- Volume 82, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 82
- Issue:
- 2021
- Issue Sort Value:
- 2021-0082-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Revision RSA -- Primary stability -- Humeral bone loss
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2021.105283 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17407.xml