Monitoring phenylalanine concentrations in the follow‐up of phenylketonuria patients: An inventory of pre‐analytical and analytical variation. Issue 1 (22nd November 2020)
- Record Type:
- Journal Article
- Title:
- Monitoring phenylalanine concentrations in the follow‐up of phenylketonuria patients: An inventory of pre‐analytical and analytical variation. Issue 1 (22nd November 2020)
- Main Title:
- Monitoring phenylalanine concentrations in the follow‐up of phenylketonuria patients: An inventory of pre‐analytical and analytical variation
- Authors:
- Coene, Karlien L. M.
Timmer, Corrie
Goorden, Susan M. I.
ten Hoedt, Amber E.
Kluijtmans, Leo A. J.
Janssen, Mirian C. H.
Rennings, Alexander J. M.
Prinsen, Hubertus C. M. T.
Wamelink, Mirjam M. C.
Ruijter, George J. G.
Körver‐Keularts, Irene M. L. W.
Heiner‐Fokkema, M. Rebecca
van Spronsen, Francjan J.
Hollak, Carla E.
Vaz, Frédéric M.
Bosch, Annet M.
Huigen, Marleen C. D. G. - Abstract:
- Abstract: Background: Reliable measurement of phenylalanine (Phe) is a prerequisite for adequate follow‐up of phenylketonuria (PKU) patients. However, previous studies have raised concerns on the intercomparability of plasma and dried blood spot (DBS) Phe results. In this study, we made an inventory of differences in (pre‐)analytical methodology used for Phe determination across Dutch laboratories, and compared DBS and plasma results. Methods: Through an online questionnaire, we assessed (pre‐)analytical Phe measurement procedures of seven Dutch metabolic laboratories. To investigate the difference between plasma and DBS Phe, participating laboratories received simultaneously collected plasma‐DBS sets from 23 PKU patients. In parallel, 40 sample sets of DBS spotted from either venous blood or capillary fingerprick were analyzed. Results: Our data show that there is no consistency on standard operating procedures for Phe measurement. The association of DBS to plasma Phe concentration exhibits substantial inter‐laboratory variation, ranging from a mean difference of −15.5% to +30.6% between plasma and DBS Phe concentrations. In addition, we found a mean difference of +5.8% in Phe concentration between capillary DBS and DBS prepared from venous blood. Conclusions: The results of our study point to substantial (pre‐)analytical variation in Phe measurements, implicating that bloodspot Phe results should be interpreted with caution, especially when no correction factor is applied.Abstract: Background: Reliable measurement of phenylalanine (Phe) is a prerequisite for adequate follow‐up of phenylketonuria (PKU) patients. However, previous studies have raised concerns on the intercomparability of plasma and dried blood spot (DBS) Phe results. In this study, we made an inventory of differences in (pre‐)analytical methodology used for Phe determination across Dutch laboratories, and compared DBS and plasma results. Methods: Through an online questionnaire, we assessed (pre‐)analytical Phe measurement procedures of seven Dutch metabolic laboratories. To investigate the difference between plasma and DBS Phe, participating laboratories received simultaneously collected plasma‐DBS sets from 23 PKU patients. In parallel, 40 sample sets of DBS spotted from either venous blood or capillary fingerprick were analyzed. Results: Our data show that there is no consistency on standard operating procedures for Phe measurement. The association of DBS to plasma Phe concentration exhibits substantial inter‐laboratory variation, ranging from a mean difference of −15.5% to +30.6% between plasma and DBS Phe concentrations. In addition, we found a mean difference of +5.8% in Phe concentration between capillary DBS and DBS prepared from venous blood. Conclusions: The results of our study point to substantial (pre‐)analytical variation in Phe measurements, implicating that bloodspot Phe results should be interpreted with caution, especially when no correction factor is applied. To minimize variation, we advocate pre‐analytical standardization and analytical harmonization of Phe measurements, including consensus on application of a correction factor to adjust DBS Phe to plasma concentrations. … (more)
- Is Part Of:
- JIMD reports. Volume 58:Issue 1(2021)
- Journal:
- JIMD reports
- Issue:
- Volume 58:Issue 1(2021)
- Issue Display:
- Volume 58, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 58
- Issue:
- 1
- Issue Sort Value:
- 2021-0058-0001-0000
- Page Start:
- 70
- Page End:
- 79
- Publication Date:
- 2020-11-22
- Subjects:
- bloodspot -- DBS -- hyperphenylalaninemia -- laboratory variation -- measurement -- phenylalanine -- phenylalanine -- phenylketonuria -- PKU
Metabolism, Inborn errors of -- Periodicals
Metabolism -- Disorders -- Periodicals
616.39042 - Journal URLs:
- https://onlinelibrary.wiley.com/loi/21928312 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmd2.12186 ↗
- Languages:
- English
- ISSNs:
- 2192-8304
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17416.xml