Ferroelectret film‐based patch‐type sensor for continuous blood pressure monitoring. Issue 3 (1st January 2014)
- Record Type:
- Journal Article
- Title:
- Ferroelectret film‐based patch‐type sensor for continuous blood pressure monitoring. Issue 3 (1st January 2014)
- Main Title:
- Ferroelectret film‐based patch‐type sensor for continuous blood pressure monitoring
- Authors:
- Noh, S.
Yoon, C.
Hyun, E.
Yoon, H.N.
Chung, T.J.
Park, K.S.
Kim, H.C. - Abstract:
- Abstract : A thin, flexible and skin‐attachable sensor for continuous monitoring of blood pressure is reported. The sensor was fabricated as a layered structure of ferroelectret film, specially designed electrodes and a flexible electronic circuit, which together enable simultaneous measurement of ballistocardiogram and an electrocardiogram on the human chest with minimal discomfort. To investigate the feasibility of continuous blood pressure monitoring, systolic blood pressure was estimated using the RJ interval, which is computed as the time delay between the R peak of the electrocardiogram and the J peak of the ballistocardiogram. The results indicate that the estimated systolic blood pressures are in excellent agreement with the reference values, achieving an intraclass correlation coefficient of 0.95 ( P < 0.01), and complying with the recommended guidelines from the Association for the Advancement of Medical Instrumentation in the United States and the British Hypertension Society.
- Is Part Of:
- Electronics letters. Volume 50:Issue 3(2014)
- Journal:
- Electronics letters
- Issue:
- Volume 50:Issue 3(2014)
- Issue Display:
- Volume 50, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 50
- Issue:
- 3
- Issue Sort Value:
- 2014-0050-0003-0000
- Page Start:
- 143
- Page End:
- 144
- Publication Date:
- 2014-01-01
- Subjects:
- biomedical electrodes -- biomedical electronics -- blood pressure measurement -- electrocardiography -- patient monitoring -- pressure sensors
ferroelectret film‐based patch‐type sensor -- continuous blood pressure monitoring -- thin flexible skin‐attachable sensor -- electrodes -- flexible electronic circuit -- ballistocardiogram -- electrocardiogram -- human chest -- systolic blood pressure -- RJ interval -- time delay -- R peak -- J peak -- systolic blood pressures -- intraclass correlation coefficient
Electronics -- Periodicals
621.381 - Journal URLs:
- http://digital-library.theiet.org/content/journals/el ↗
http://estar.bl.uk/cgi-bin/sciserv.pl?collection=journals&journal=00135194 ↗
https://ietresearch.onlinelibrary.wiley.com/loi/1350911x ↗
http://www.theiet.org/ ↗ - DOI:
- 10.1049/el.2013.3715 ↗
- Languages:
- English
- ISSNs:
- 0013-5194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3705.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17394.xml