Accuracy of Computer-Guided Template-Based Implant Surgery: A Computed Tomography–Based Clinical Follow-Up Study. Issue 6 (December 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy of Computer-Guided Template-Based Implant Surgery: A Computed Tomography–Based Clinical Follow-Up Study. Issue 6 (December 2019)
- Main Title:
- Accuracy of Computer-Guided Template-Based Implant Surgery
- Authors:
- Schelbert, Tobias
Gander, Thomas
Blumer, Michael
Jung, Ronald
Rücker, Martin
Rostetter, Claudio - Abstract:
- Abstract : Objective: The aim of this clinical study was to analyze the accuracy of computer-guided implant surgery. Materials and Methods: Assisted by computed tomography (CT)-based planning software and navigational templates, 16 patients successfully received 26 dental implants. Each implant parameter (a–d) was calculated based on superimposed preoperative and postoperative cone beam CT scans: (a) deviation at entry point; (b) deviation at apex; (c) angular deviation; and (d) depth deviation. Results: Mean central deviation at implant entry point and apex was 0.91 mm (standard error [SE] = 0.11 mm; 95% confidence interval [CI]: 0.69–1.13) and 1.22 mm (SE = 0.11 mm; 95% CI: 0.99–1.45), respectively. Mean angulation deviation was 4.11 degrees (SE = 0.52 degrees; 95% CI: 3.04–5.17) and the average depth deviation was 0.65 mm (SE = 0.11 mm; 95% CI: 0.42–0.87). For the total number of implants placed, the maximum error was 2.34 mm at entry point, 2.71 mm at apex, 9.44 degrees in angular deviation, and 2.00 mm in depth deviation. Conclusion: Great accuracy was reached even in advanced cases with prior bone augmentation and complex traumas. This leads to the conclusion that particularly in advanced cases, computer-guided implantation can be beneficial.
- Is Part Of:
- Implant dentistry. Volume 28:Issue 6(2019)
- Journal:
- Implant dentistry
- Issue:
- Volume 28:Issue 6(2019)
- Issue Display:
- Volume 28, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 6
- Issue Sort Value:
- 2019-0028-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- template-guided -- bone augmentation -- computer-aided -- cone beam computed tomography
Dental implants -- Periodicals
617.69305 - Journal URLs:
- http://journals.lww.com/implantdent/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00008505-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ID.0000000000000936 ↗
- Languages:
- English
- ISSNs:
- 1056-6163
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4371.436300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21960.xml