Transcutaneous carbon dioxide measurements in fruits, vegetables and humans: A prospective observational study. Issue 12 (December 2019)
- Record Type:
- Journal Article
- Title:
- Transcutaneous carbon dioxide measurements in fruits, vegetables and humans: A prospective observational study. Issue 12 (December 2019)
- Main Title:
- Transcutaneous carbon dioxide measurements in fruits, vegetables and humans
- Authors:
- Sochet, Anthony A.
Bessone, Stacey K.
Parilla, Nick W.
Nakagawa, Thomas A. - Abstract:
- Abstract : BACKGROUND: Transcutaneous carbon dioxide measurement (Tc CO2 ) is frequently used as a surrogate for arterial blood gas sampling in adults and children with critical illness. Data from noninvasive Tc CO2 monitoring assists with clinical decisions regarding mechanical ventilation settings, estimation of metabolic consumption and determination of adequate end-organ tissue perfusion. OBJECTIVES: To report Tc CO2 values obtained from various fruits, vegetables and elite critical care medicine specialists. DESIGN: Prospective, observational, nonblinded cohort study. SETTINGS: Single-centre, tertiary paediatric referral centre and organic farmers' market. PARTICIPANTS: Vegetables and fruits included 10 samples of each of the following: red delicious apple ( Malus domestica ), manzano banana ( Musa sapientum ), key lime ( Citrus aurantiifolia ), miniature sweet bell pepper ( Capsicum annuum ), sweet potato ( Ipomoea batatas ) and avocado ( Persea americana ). Ten human controls were studied including a paediatric intensivist, a paediatric inpatient hospital physician, four paediatric resident physicians and four paediatric critical care nurses. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Tc CO2 values for each species and device response times. RESULTS: Tc CO2 readings were measurable in all study species except the sweet potato. Mean ± SD values of Tc CO2 for human controls [4.34 ± 0.37 kPa (32.6 ± 2.8 mmHg)] were greater than apples [3.09 ± 0.19 kPa (23.2 ± 1.4 mmHg),Abstract : BACKGROUND: Transcutaneous carbon dioxide measurement (Tc CO2 ) is frequently used as a surrogate for arterial blood gas sampling in adults and children with critical illness. Data from noninvasive Tc CO2 monitoring assists with clinical decisions regarding mechanical ventilation settings, estimation of metabolic consumption and determination of adequate end-organ tissue perfusion. OBJECTIVES: To report Tc CO2 values obtained from various fruits, vegetables and elite critical care medicine specialists. DESIGN: Prospective, observational, nonblinded cohort study. SETTINGS: Single-centre, tertiary paediatric referral centre and organic farmers' market. PARTICIPANTS: Vegetables and fruits included 10 samples of each of the following: red delicious apple ( Malus domestica ), manzano banana ( Musa sapientum ), key lime ( Citrus aurantiifolia ), miniature sweet bell pepper ( Capsicum annuum ), sweet potato ( Ipomoea batatas ) and avocado ( Persea americana ). Ten human controls were studied including a paediatric intensivist, a paediatric inpatient hospital physician, four paediatric resident physicians and four paediatric critical care nurses. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Tc CO2 values for each species and device response times. RESULTS: Tc CO2 readings were measurable in all study species except the sweet potato. Mean ± SD values of Tc CO2 for human controls [4.34 ± 0.37 kPa (32.6 ± 2.8 mmHg)] were greater than apples [3.09 ± 0.19 kPa (23.2 ± 1.4 mmHg), P < 0.01], bananas [2.73 ± 0.28 kPa (20.5 ± 2.1 mmHg), P < 0.01] and limes [2.76 ± 0.52 kPa (20.7 ± 3.9 mmHg), P < 0.01] but no different to those of avocados [4.29 ± 0.44 kPa (32.2 ± 3.3 mmHg), P = 0.77] and bell peppers [4.19 ± 1.13 kPa (31.4 ± 8.5 mmHg), P = 0.68]. Transcutaneous response times did not differ between research cohorts and human controls. CONCLUSION: We found nonroot, nontuberous vegetables to have Tc CO2 values similar to that of healthy, human controls. Fruits yield Tc CO2 readings, but substantially lower than human controls. … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 36:Issue 12(2019:Dec.)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 36:Issue 12(2019:Dec.)
- Issue Display:
- Volume 36, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 36
- Issue:
- 12
- Issue Sort Value:
- 2019-0036-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000001073 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17368.xml