CT reconstruction with thick slices not only underestimates lymph node size but also reduces data reproducibility in colorectal cancer. (October 2021)
- Record Type:
- Journal Article
- Title:
- CT reconstruction with thick slices not only underestimates lymph node size but also reduces data reproducibility in colorectal cancer. (October 2021)
- Main Title:
- CT reconstruction with thick slices not only underestimates lymph node size but also reduces data reproducibility in colorectal cancer
- Authors:
- Onuma, Yurina
Tsuruta, Chie
Okita, Kenji
Hamabe, Atsushi
Ogura, Keishi
Takemasa, Ichiro
Hatakenaka, Masamitsu - Abstract:
- Background: Reliable size measurement of lymph node (LN) metastases is important for the evaluation of cancer treatment. However, image analyses without proper settings may result in inappropriate diagnoses and staging. Purpose: To investigate whether reconstruction slice thickness in computed tomography (CT) affects measurements of LN size and reproducibility. Material and Methods: We analyzed 48 patients with histological diagnoses of sigmoid colon and rectal cancer who underwent contrast-enhanced CT colonography as part of a surgical treatment preparation. A board-certified radiologist selected 106 LNs whose short-axis diameter was ≥5 mm on 1-mm-thick images; the short-axis diameters were measured on 1- and 5-mm-thick images by the radiologist and residents and compared using Wilcoxon matched-pairs signed rank test. Data variation and reproducibility were evaluated using the F test and Bland–Altman analysis. P <0.05 was considered significant. Results: Short-axis diameters measured on 5-mm-thick images were significantly lower than those measured on 1-mm-thick images ( P <0.01), even in the LNs whose short-axis diameters were over twice the slice thickness ( P <0.05). Of the 106 LNs, 57 showed short-axis diameter <5 mm on 5-mm-thick images; the maximum short-axis diameter was 6.7 mm on a 1-mm thick image. Data variation was significantly larger on 5-mm thick images than 1-mm-thick images in small LNs ( P <0.05) and reproducibility on 5-mm-thick images was inferior to thatBackground: Reliable size measurement of lymph node (LN) metastases is important for the evaluation of cancer treatment. However, image analyses without proper settings may result in inappropriate diagnoses and staging. Purpose: To investigate whether reconstruction slice thickness in computed tomography (CT) affects measurements of LN size and reproducibility. Material and Methods: We analyzed 48 patients with histological diagnoses of sigmoid colon and rectal cancer who underwent contrast-enhanced CT colonography as part of a surgical treatment preparation. A board-certified radiologist selected 106 LNs whose short-axis diameter was ≥5 mm on 1-mm-thick images; the short-axis diameters were measured on 1- and 5-mm-thick images by the radiologist and residents and compared using Wilcoxon matched-pairs signed rank test. Data variation and reproducibility were evaluated using the F test and Bland–Altman analysis. P <0.05 was considered significant. Results: Short-axis diameters measured on 5-mm-thick images were significantly lower than those measured on 1-mm-thick images ( P <0.01), even in the LNs whose short-axis diameters were over twice the slice thickness ( P <0.05). Of the 106 LNs, 57 showed short-axis diameter <5 mm on 5-mm-thick images; the maximum short-axis diameter was 6.7 mm on a 1-mm thick image. Data variation was significantly larger on 5-mm thick images than 1-mm-thick images in small LNs ( P <0.05) and reproducibility on 5-mm-thick images was inferior to that on 1-mm-thick images. Conclusion: Thick reconstruction slices in CT can result in an underestimation of LN size and reduce data reproducibility. When measuring LN size, a thin reconstruction slice would be recommended based on targeted LN size. … (more)
- Is Part Of:
- Acta radiologica. Volume 62:Number 10(2021)
- Journal:
- Acta radiologica
- Issue:
- Volume 62:Number 10(2021)
- Issue Display:
- Volume 62, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 62
- Issue:
- 10
- Issue Sort Value:
- 2021-0062-0010-0000
- Page Start:
- 1275
- Page End:
- 1282
- Publication Date:
- 2021-10
- Subjects:
- Computed tomography -- slice thickness -- lymph node -- short-axis diameter -- reproducibility
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185120968569 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18087.xml