Low-Radiation-Dose Stress Myocardial Perfusion Measurement Using First-Pass Analysis Dynamic Computed Tomography: A Preliminary Investigation in a Swine Model. Issue 12 (December 2019)
- Record Type:
- Journal Article
- Title:
- Low-Radiation-Dose Stress Myocardial Perfusion Measurement Using First-Pass Analysis Dynamic Computed Tomography: A Preliminary Investigation in a Swine Model. Issue 12 (December 2019)
- Main Title:
- Low-Radiation-Dose Stress Myocardial Perfusion Measurement Using First-Pass Analysis Dynamic Computed Tomography
- Authors:
- Hubbard, Logan
Malkasian, Shant
Zhao, Yixiao
Abbona, Pablo
Kwon, Jungnam
Molloi, Sabee - Abstract:
- Abstract : Objectives: The aim of this study was to assess the feasibility of a prospective first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique for accurate low-radiation-dose global stress perfusion measurement. Materials and Methods: The prospective FPA technique was evaluated in 10 swine (42 ± 12 kg) by direct comparison to a previously validated retrospective FPA technique. Of the 10 swine, 3 had intermediate stenoses with fractional flow reserve severities of 0.70 to 0.90. In each swine, contrast and saline were injected peripherally followed by dynamic volume scanning with a 320-slice CT scanner. Specifically, for the reference standard retrospective FPA technique, volume scans were acquired continuously at 100 kVp and 200 mA over 15 to 20 seconds, followed by systematic selection of only 2 volume scans for global perfusion measurement. For the prospective FPA technique, only 2 volume scans were acquired at 100 kVp and 50 mA for global perfusion measurement. All prospective global stress perfusion measurements were then compared with the corresponding reference standard retrospective global stress perfusion measurements through regression analysis. The CTDIvol 32 and size-specific dose estimate of the prospective FPA technique were also determined. Results: All prospective global stress perfusion measurements (PPRO ) at 50 mA were in good agreement with the reference standard retrospective global stress perfusion measurements (PREF ) at 200Abstract : Objectives: The aim of this study was to assess the feasibility of a prospective first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique for accurate low-radiation-dose global stress perfusion measurement. Materials and Methods: The prospective FPA technique was evaluated in 10 swine (42 ± 12 kg) by direct comparison to a previously validated retrospective FPA technique. Of the 10 swine, 3 had intermediate stenoses with fractional flow reserve severities of 0.70 to 0.90. In each swine, contrast and saline were injected peripherally followed by dynamic volume scanning with a 320-slice CT scanner. Specifically, for the reference standard retrospective FPA technique, volume scans were acquired continuously at 100 kVp and 200 mA over 15 to 20 seconds, followed by systematic selection of only 2 volume scans for global perfusion measurement. For the prospective FPA technique, only 2 volume scans were acquired at 100 kVp and 50 mA for global perfusion measurement. All prospective global stress perfusion measurements were then compared with the corresponding reference standard retrospective global stress perfusion measurements through regression analysis. The CTDIvol 32 and size-specific dose estimate of the prospective FPA technique were also determined. Results: All prospective global stress perfusion measurements (PPRO ) at 50 mA were in good agreement with the reference standard retrospective global stress perfusion measurements (PREF ) at 200 mA (PPRO = 1.07 PREF −0.09, r = 0.94; root-mean-square error = 0.30 mL/min per gram). The CTDIvol 32 and size-specific dose estimate of the prospective FPA technique were 2.3 and 3.7 mGy, respectively. Conclusions: Accurate low-radiation-dose global stress perfusion measurement is feasible using a prospective FPA dynamic CT perfusion technique. … (more)
- Is Part Of:
- Investigative radiology. Volume 54:Issue 12(2019)
- Journal:
- Investigative radiology
- Issue:
- Volume 54:Issue 12(2019)
- Issue Display:
- Volume 54, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 54
- Issue:
- 12
- Issue Sort Value:
- 2019-0054-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- coronary artery disease -- myocardial perfusion imaging -- dynamic computed tomography -- dose reduction
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000613 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18686.xml