Thermal considerations for microswimmer trap-and-release using standing surface acoustic waves. Issue 13 (17th May 2021)
- Record Type:
- Journal Article
- Title:
- Thermal considerations for microswimmer trap-and-release using standing surface acoustic waves. Issue 13 (17th May 2021)
- Main Title:
- Thermal considerations for microswimmer trap-and-release using standing surface acoustic waves
- Authors:
- Cui, Mingyang
Kim, Minji
Weisensee, Patricia B.
Meacham, J. Mark - Abstract:
- Abstract : Glass-based surface acoustic wave (SAW) devices enable trapping and analysis of swimming Chlamydomonas reinhardtii cells without the excessive heating associated with PDMS-based SAW devices. Abstract : Controlled trapping of cells and microorganisms using substrate acoustic waves (SAWs; conventionally termed surface acoustic waves) has proven useful in numerous biological and biomedical applications owing to the label- and contact-free nature of acoustic confinement. However, excessive heating due to vibration damping and other system losses potentially compromises the biocompatibility of the SAW technique. Herein, we investigate the thermal biocompatibility of polydimethylsiloxane (PDMS)-based SAW and glass-based SAW [that supports a bulk acoustic wave (BAW) in the fluid domain] devices operating at different frequencies and applied voltages. First, we use infrared thermography to produce heat maps of regions of interest (ROI) within the aperture of the SAW transducers for PDMS- and glass-based devices. Motile Chlamydomonas reinhardtii algae cells are then used to test the trapping performance and biocompatibility of these devices. At low input power, the PDMS-based SAW system cannot generate a large enough acoustic trapping force to hold swimming C. reinhardtii cells. At high input power, the temperature of this device rises rapidly, damaging (and possibly killing) the cells. The glass-based SAW/BAW hybrid system, on the other hand, can not only trap swimming C.Abstract : Glass-based surface acoustic wave (SAW) devices enable trapping and analysis of swimming Chlamydomonas reinhardtii cells without the excessive heating associated with PDMS-based SAW devices. Abstract : Controlled trapping of cells and microorganisms using substrate acoustic waves (SAWs; conventionally termed surface acoustic waves) has proven useful in numerous biological and biomedical applications owing to the label- and contact-free nature of acoustic confinement. However, excessive heating due to vibration damping and other system losses potentially compromises the biocompatibility of the SAW technique. Herein, we investigate the thermal biocompatibility of polydimethylsiloxane (PDMS)-based SAW and glass-based SAW [that supports a bulk acoustic wave (BAW) in the fluid domain] devices operating at different frequencies and applied voltages. First, we use infrared thermography to produce heat maps of regions of interest (ROI) within the aperture of the SAW transducers for PDMS- and glass-based devices. Motile Chlamydomonas reinhardtii algae cells are then used to test the trapping performance and biocompatibility of these devices. At low input power, the PDMS-based SAW system cannot generate a large enough acoustic trapping force to hold swimming C. reinhardtii cells. At high input power, the temperature of this device rises rapidly, damaging (and possibly killing) the cells. The glass-based SAW/BAW hybrid system, on the other hand, can not only trap swimming C. reinhardtii at low input power, but also exhibits better thermal biocompatibility than the PDMS-based SAW system at high input power. Thus, a glass-based SAW/BAW device creates strong acoustic trapping forces in a biocompatible environment, providing a new solution to safely trap active microswimmers for research involving motile cells and microorganisms. … (more)
- Is Part Of:
- Lab on a chip. Volume 21:Issue 13(2021)
- Journal:
- Lab on a chip
- Issue:
- Volume 21:Issue 13(2021)
- Issue Display:
- Volume 21, Issue 13 (2021)
- Year:
- 2021
- Volume:
- 21
- Issue:
- 13
- Issue Sort Value:
- 2021-0021-0013-0000
- Page Start:
- 2534
- Page End:
- 2543
- Publication Date:
- 2021-05-17
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1lc00257k ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17346.xml