A real-time LAMP-based dual-sample microfluidic chip for rapid and simultaneous detection of multiple waterborne pathogenic bacteria from coastal waters. Issue 24 (27th May 2021)
- Record Type:
- Journal Article
- Title:
- A real-time LAMP-based dual-sample microfluidic chip for rapid and simultaneous detection of multiple waterborne pathogenic bacteria from coastal waters. Issue 24 (27th May 2021)
- Main Title:
- A real-time LAMP-based dual-sample microfluidic chip for rapid and simultaneous detection of multiple waterborne pathogenic bacteria from coastal waters
- Authors:
- Jin, Jinglei
Duan, Lijun
Fu, Jiali
Chai, Fangchao
Zhou, Qianjin
Wang, Yaohua
Shao, Xinbin
Wang, Lei
Yan, Maocang
Su, Xiurong
Zhang, Yanjun
Pan, Junhang
Chen, Jiong - Abstract:
- Abstract : (1) A dual-sample microfluidic chip integrated LAMP method was developed to simultaneously detect 10 waterborne pathogenic bacteria within 35 min. (2) Its operations are in a highly automated format and it is suitable for on-site detection. Abstract : Waterborne pathogens are becoming a serious worldwide health hazard; thus, the regular monitoring of epidemic pathogens is urgently required for public safety. In the present study, we developed a microfluidic chip integrated loop-mediated isothermal amplification technique (on-chip LAMP) to simultaneously detect 10 waterborne pathogenic bacteria, Campylobacter jejuni, Listeria monocytogenes, Salmonella enterica, Shigella flexneri, Staphylococcus aureus, Vibrio alginolyticus, V. cholerae, V. parahemolyticus, V. vulnificus, and Yersinia enterocolitica . This method was capable of simultaneously completing 22 genetic analyses of two specimens and achieved limits of detection ranging from 7.92 × 10 −3 to 9.54 × 10 −1 pg of genomic DNA of pure bacteria per reaction. The processes from sample loading to microfluidic operation were in a highly automated format, and the LAMP reaction ran to completion within 35 minutes, with a minimal volume of 22 μl per each half of a single chip. The coefficient of variation for the time-to-positive value was less than 0.1, indicating an excellent reproducibility of the dual-sample on-chip LAMP assay. The clinical sensitivity and specificity in analyses of coastal water samples were 93.1%Abstract : (1) A dual-sample microfluidic chip integrated LAMP method was developed to simultaneously detect 10 waterborne pathogenic bacteria within 35 min. (2) Its operations are in a highly automated format and it is suitable for on-site detection. Abstract : Waterborne pathogens are becoming a serious worldwide health hazard; thus, the regular monitoring of epidemic pathogens is urgently required for public safety. In the present study, we developed a microfluidic chip integrated loop-mediated isothermal amplification technique (on-chip LAMP) to simultaneously detect 10 waterborne pathogenic bacteria, Campylobacter jejuni, Listeria monocytogenes, Salmonella enterica, Shigella flexneri, Staphylococcus aureus, Vibrio alginolyticus, V. cholerae, V. parahemolyticus, V. vulnificus, and Yersinia enterocolitica . This method was capable of simultaneously completing 22 genetic analyses of two specimens and achieved limits of detection ranging from 7.92 × 10 −3 to 9.54 × 10 −1 pg of genomic DNA of pure bacteria per reaction. The processes from sample loading to microfluidic operation were in a highly automated format, and the LAMP reaction ran to completion within 35 minutes, with a minimal volume of 22 μl per each half of a single chip. The coefficient of variation for the time-to-positive value was less than 0.1, indicating an excellent reproducibility of the dual-sample on-chip LAMP assay. The clinical sensitivity and specificity in analyses of coastal water samples were 93.1% and 98.0%, respectively, in comparison with traditional microbiological methods. Our established dual-sample on-chip LAMP assay provides an effective multiple-pathogen analysis of waterborne bacterial pathogens. This indicates that the method is applicable for on-site detection and routine monitoring of waterborne bacteria in aquatic environments. … (more)
- Is Part Of:
- Analytical methods. Volume 13:Issue 24(2021)
- Journal:
- Analytical methods
- Issue:
- Volume 13:Issue 24(2021)
- Issue Display:
- Volume 13, Issue 24 (2021)
- Year:
- 2021
- Volume:
- 13
- Issue:
- 24
- Issue Sort Value:
- 2021-0013-0024-0000
- Page Start:
- 2710
- Page End:
- 2721
- Publication Date:
- 2021-05-27
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1ay00492a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17347.xml