Medina® Embolization Device for the Treatment of Intracranial Aneurysms: Safety and Angiographic Effectiveness at 6 Months. Issue 2 (10th April 2017)
- Record Type:
- Journal Article
- Title:
- Medina® Embolization Device for the Treatment of Intracranial Aneurysms: Safety and Angiographic Effectiveness at 6 Months. Issue 2 (10th April 2017)
- Main Title:
- Medina® Embolization Device for the Treatment of Intracranial Aneurysms: Safety and Angiographic Effectiveness at 6 Months
- Authors:
- Sourour, Nader-Antoine
Vande Perre, Saskia
Maria, Federico Di
Papagiannaki, Chrysanthi
Gabrieli, Joseph
Pistocchi, Silvia
Bartolini, Bruno
Degos, Vincent
Carpentier, Alexandre
Chiras, Jacques
Clarençon, Frédéric - Abstract:
- Abstract: BACKGROUND: The Medina Embolization Device (MED) is a new concept device that combines the design of a detachable coil and the one of an intrasaccular flow disruption device. OBJECTIVE: To evaluate the feasibility, safety, and 6- to 9-mo effectiveness of this new device for the treatment of intracranial wide-necked aneurysms. METHODS: Twelve patients (10 females, mean age = 56 yr) with 13 wide-necked intracranial aneurysms (3 ruptured; 10 unruptured) were treated by means of the MED from January 2015 to October 2015. In 15% of the cases, MEDs were used in a standalone fashion; in 85% of the cases, additional regular coils were used. Adjunctive compliant balloon was used in 4 of 13 cases (31%). Procedure-related complications were systematically recorded; discharge and 6- to 9-mo follow-up modified Rankin Scale was assessed. Angiographic follow-up was performed with a mean delay of 5.5 ± 1.7 mo. Occlusion rate was evaluated in postprocedure and at midterm follow-up using the Roy–Raymond scale. RESULTS: The deployment of the MED was feasible in all cases. No perforation was recorded. One case of thromboembolic complication was observed in a ruptured anterior communicating artery aneurysm, without any clinical consequence at follow-up. Grade A occlusion rate was 61.5% in postprocedure and 83% at 6-mo follow-up. Two cases (17%) of recanalization were documented angiographically. CONCLUSION: The MED is a new generation device combining the design of a detachable coilAbstract: BACKGROUND: The Medina Embolization Device (MED) is a new concept device that combines the design of a detachable coil and the one of an intrasaccular flow disruption device. OBJECTIVE: To evaluate the feasibility, safety, and 6- to 9-mo effectiveness of this new device for the treatment of intracranial wide-necked aneurysms. METHODS: Twelve patients (10 females, mean age = 56 yr) with 13 wide-necked intracranial aneurysms (3 ruptured; 10 unruptured) were treated by means of the MED from January 2015 to October 2015. In 15% of the cases, MEDs were used in a standalone fashion; in 85% of the cases, additional regular coils were used. Adjunctive compliant balloon was used in 4 of 13 cases (31%). Procedure-related complications were systematically recorded; discharge and 6- to 9-mo follow-up modified Rankin Scale was assessed. Angiographic follow-up was performed with a mean delay of 5.5 ± 1.7 mo. Occlusion rate was evaluated in postprocedure and at midterm follow-up using the Roy–Raymond scale. RESULTS: The deployment of the MED was feasible in all cases. No perforation was recorded. One case of thromboembolic complication was observed in a ruptured anterior communicating artery aneurysm, without any clinical consequence at follow-up. Grade A occlusion rate was 61.5% in postprocedure and 83% at 6-mo follow-up. Two cases (17%) of recanalization were documented angiographically. CONCLUSION: The MED is a new generation device combining the design of a detachable coil and an intrasaccular flow disruption device. According to our early experience, this device is safe and provides a satisfactory occlusion rate at angiographic follow-up of 6 mo. … (more)
- Is Part Of:
- Neurosurgery. Volume 82:Issue 2(2018)
- Journal:
- Neurosurgery
- Issue:
- Volume 82:Issue 2(2018)
- Issue Display:
- Volume 82, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 82
- Issue:
- 2
- Issue Sort Value:
- 2018-0082-0002-0000
- Page Start:
- 155
- Page End:
- 162
- Publication Date:
- 2017-04-10
- Subjects:
- Medina Embolization Device -- Intrasaccular flow disruption -- Petals -- Intracranial aneurysm
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyx161 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17342.xml