Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report. Issue 1 (4th February 2020)
- Record Type:
- Journal Article
- Title:
- Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report. Issue 1 (4th February 2020)
- Main Title:
- Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report
- Authors:
- Jimba, Takahiro
Hashikata, Takehiro
Matsushita, Masashiro
Yamasaki, Masao - Editors:
- Farag, Mohamed F
Gue, Ying Xuan
Shaheen, Sameh
Carazo, Carlos Minguito
Memtsas, Vassilios Parisis - Abstract:
- Abstract: Background : Hypersensitivity reaction is a classic cause of in-stent restenosis (ISR) in coronary stents, typically reported in bare-metal stents and first-generation drug-eluting stents. Biodegradable polymer sirolimus-eluting stent (BP-SES) was developed with the concept of biocompatibility, and there has been no report of ISR of BP-SES with hypersensitivity reaction. Case summary : An 81-year-old woman presented with ST-elevation acute inferior myocardial infarction. Primary percutaneous coronary intervention was performed for the culprit lesion in the left circumflex artery with a permanent polymer everolimus-eluting stent (PP-EES), followed by BP-SES implantation in the left anterior descending artery. Eight months later, coronary angiography showed total occlusion of the PP-EES and diffuse ISR in the BP-SES, treated with a paclitaxel-eluting balloon. Fluorodeoxyglucose with positron emission tomography showed increased uptake around the BP-SES, and cardiac magnetic resonance imaging revealed a late gadolinium-enhanced area around both stents. Four months later, she developed re-ISR in the BP-SES, and optical coherence tomography demonstrated diffuse-layered neointimal hyperplasia with microvascularization and peri-strut low-intensity area. She was successfully treated with coronary artery bypass grafting. Discussion : Our case demonstrated repetitive short-term ISR of the BP-SES. Observation by both intravascular and non-invasive imaging modalities suggestedAbstract: Background : Hypersensitivity reaction is a classic cause of in-stent restenosis (ISR) in coronary stents, typically reported in bare-metal stents and first-generation drug-eluting stents. Biodegradable polymer sirolimus-eluting stent (BP-SES) was developed with the concept of biocompatibility, and there has been no report of ISR of BP-SES with hypersensitivity reaction. Case summary : An 81-year-old woman presented with ST-elevation acute inferior myocardial infarction. Primary percutaneous coronary intervention was performed for the culprit lesion in the left circumflex artery with a permanent polymer everolimus-eluting stent (PP-EES), followed by BP-SES implantation in the left anterior descending artery. Eight months later, coronary angiography showed total occlusion of the PP-EES and diffuse ISR in the BP-SES, treated with a paclitaxel-eluting balloon. Fluorodeoxyglucose with positron emission tomography showed increased uptake around the BP-SES, and cardiac magnetic resonance imaging revealed a late gadolinium-enhanced area around both stents. Four months later, she developed re-ISR in the BP-SES, and optical coherence tomography demonstrated diffuse-layered neointimal hyperplasia with microvascularization and peri-strut low-intensity area. She was successfully treated with coronary artery bypass grafting. Discussion : Our case demonstrated repetitive short-term ISR of the BP-SES. Observation by both intravascular and non-invasive imaging modalities suggested the presence of hypersensitivity reaction localized in the stent. Hypersensitivity to the metal may be a possible mechanism because both stents are composed of L605 cobalt–chromium alloy. This is the first report of ISR of a BP-SES with hypersensitivity reaction. Non-invasive imaging can be useful to assess this critical condition. … (more)
- Is Part Of:
- European heart journal. Volume 4:Issue 1(2020)
- Journal:
- European heart journal
- Issue:
- Volume 4:Issue 1(2020)
- Issue Display:
- Volume 4, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 1
- Issue Sort Value:
- 2020-0004-0001-0000
- Page Start:
- 1
- Page End:
- 5
- Publication Date:
- 2020-02-04
- Subjects:
- Drug-eluting stent -- In-stent restenosis -- Biodegradable polymer sirolimus-eluting stent -- Hypersensitivity reaction -- Case report
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytaa001 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17339.xml