Quantification of magnetic susceptibility fingerprint of a 3D linearity medical device. (July 2021)
- Record Type:
- Journal Article
- Title:
- Quantification of magnetic susceptibility fingerprint of a 3D linearity medical device. (July 2021)
- Main Title:
- Quantification of magnetic susceptibility fingerprint of a 3D linearity medical device
- Authors:
- Stanescu, T.
Mousavi, S.H.
Cole, M.
Barberi, E.
Wachowicz, K. - Abstract:
- Highlights: Modelling method for magnetic susceptibility effects applied to QA/QC devices. Approach demonstrated in the case of a 3D linearity phantom. Approach allows the phantom to characterize both GNL and B0 components. Allows B0 mapping measurements in extended FOVs. MR QA simplified with only two measurements and a single phantom. Abstract: Purpose: The study investigates the numerical modelling as well as experimental validation of magnetic susceptibility effects with respect to a 3D linearity phantom used for the quantification of MR image distortions. Methods: Magnetic field numerical simulations based on finite difference methods were conducted to generate the susceptibility ( χ ) model of the MRID 3D phantom. Experimental data was acquired and analyzed for eight different MR scanners to include a wide range of scanning parameters. Distortion vector fields were generated by applying a harmonic analysis based on finite elements methods. Phantom scans for the same setup but with opposite polarities of the frequency encoding gradient were processed in conjunction with the susceptibility modelling to separately quantify three field components due to gradient non-linearities (GNL), B0 inhomogeneities and χ perturbations. Results: The numerical modelling showed a significant range of χ value of up to 8.23 ppm, with a mean value of 2.9 ppm. The χ perturbations were found to be mostly present at the end plates of the cylindrical phantom design. The simulations alsoHighlights: Modelling method for magnetic susceptibility effects applied to QA/QC devices. Approach demonstrated in the case of a 3D linearity phantom. Approach allows the phantom to characterize both GNL and B0 components. Allows B0 mapping measurements in extended FOVs. MR QA simplified with only two measurements and a single phantom. Abstract: Purpose: The study investigates the numerical modelling as well as experimental validation of magnetic susceptibility effects with respect to a 3D linearity phantom used for the quantification of MR image distortions. Methods: Magnetic field numerical simulations based on finite difference methods were conducted to generate the susceptibility ( χ ) model of the MRID 3D phantom. Experimental data was acquired and analyzed for eight different MR scanners to include a wide range of scanning parameters. Distortion vector fields were generated by applying a harmonic analysis based on finite elements methods. Phantom scans for the same setup but with opposite polarities of the frequency encoding gradient were processed in conjunction with the susceptibility modelling to separately quantify three field components due to gradient non-linearities (GNL), B0 inhomogeneities and χ perturbations. Results: The numerical modelling showed a significant range of χ value of up to 8.23 ppm, with a mean value of 2.9 ppm. The χ perturbations were found to be mostly present at the end plates of the cylindrical phantom design. The simulations also showed that setup rotations of up to 10° introduced only negligible variations in the χ model of less than 0.1 ppm. This allows for a straightforward practical implementation of the modelling as a single lookup table. After correcting for the χ perturbations, the B 0 inhomogeneities were derived and found to be in good agreement with either the MR system manufacturer specifications or experimental data available in the literature. Conclusions: It is possible to accurately model the magnetic susceptibility signature of a 3D linearity device and remove it as a post-processing correction step. This is important as the procedure unlocks the ability of determining both the GNL field and B0 map of the scanner without the need of extra acquisitions or phantoms. … (more)
- Is Part Of:
- Physica medica. Volume 87(2021)
- Journal:
- Physica medica
- Issue:
- Volume 87(2021)
- Issue Display:
- Volume 87, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 87
- Issue:
- 2021
- Issue Sort Value:
- 2021-0087-2021-0000
- Page Start:
- 39
- Page End:
- 48
- Publication Date:
- 2021-07
- Subjects:
- Magnetic susceptibility -- Numerical simulations -- Finite difference method -- Harmonic analysis -- MR image distortions -- MR-guided radiation therapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.05.023 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17324.xml