Potential infection risk assessment of improper bioaerosol experiment operation in one BSL-3 laboratory based on the improved Wells-Riley method. (15th August 2021)
- Record Type:
- Journal Article
- Title:
- Potential infection risk assessment of improper bioaerosol experiment operation in one BSL-3 laboratory based on the improved Wells-Riley method. (15th August 2021)
- Main Title:
- Potential infection risk assessment of improper bioaerosol experiment operation in one BSL-3 laboratory based on the improved Wells-Riley method
- Authors:
- Liu, Zhijian
Zhuang, Wenbin
Hu, Xiaoqi
Zhao, Zhiheng
Rong, Rui
Li, Jinsong
Li, Na
Ding, Wenjun - Abstract:
- Abstract: Laboratory-acquired infection caused by improper operation in the course of experimental process is frequently reported, so the exposure risk study of biosafety laboratory has become a top priority. In this study, the infection risk of bioaerosols under three typical improper operations was investigated by means of Computational Fluid Dynamics (CFD) method coupled with Wells-Riley equation based on one typical BSL-3 laboratory bioaerosol releasing experiment. Filed measurement of concentrations of two bioaerosols ( Serratia marcescens and phage ΦX174) were used to verify the accuracy of the CFD model. Combined with air-age isosurface map, the potential infection risk and time disinfection law were explored in detail. The results showed that the air recirculation zone of the laboratory is mainly located near the experimental equipments, and the bioaerosol removal efficiency in regions above 1.5 m is low. The risk of infection in different regions varied by more than 20 times. In addition, the potential exposure per minute was higher at the beginning of the leak, and the risk value was maintained at about 1%/min after 4 min. These findings provide some guidance suggestions for disinfection procedures that the first is to avoid the initial exposure of leakage, and the second is to grasp high-risk targeted disinfection location. Highlights: Bioaerosol infection risk of improper operation in a BSL-3 laboratory was evaluated. High-risk regions combined with air-ageAbstract: Laboratory-acquired infection caused by improper operation in the course of experimental process is frequently reported, so the exposure risk study of biosafety laboratory has become a top priority. In this study, the infection risk of bioaerosols under three typical improper operations was investigated by means of Computational Fluid Dynamics (CFD) method coupled with Wells-Riley equation based on one typical BSL-3 laboratory bioaerosol releasing experiment. Filed measurement of concentrations of two bioaerosols ( Serratia marcescens and phage ΦX174) were used to verify the accuracy of the CFD model. Combined with air-age isosurface map, the potential infection risk and time disinfection law were explored in detail. The results showed that the air recirculation zone of the laboratory is mainly located near the experimental equipments, and the bioaerosol removal efficiency in regions above 1.5 m is low. The risk of infection in different regions varied by more than 20 times. In addition, the potential exposure per minute was higher at the beginning of the leak, and the risk value was maintained at about 1%/min after 4 min. These findings provide some guidance suggestions for disinfection procedures that the first is to avoid the initial exposure of leakage, and the second is to grasp high-risk targeted disinfection location. Highlights: Bioaerosol infection risk of improper operation in a BSL-3 laboratory was evaluated. High-risk regions combined with air-age isosurface map in a BSL-3 laboratory was explored. Time distribution trend of infection probability in the high-risk region was calculated. Some reasonable guidance suggestions for disinfection time schedule were proposed. … (more)
- Is Part Of:
- Building and environment. Volume 201(2021)
- Journal:
- Building and environment
- Issue:
- Volume 201(2021)
- Issue Display:
- Volume 201, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 201
- Issue:
- 2021
- Issue Sort Value:
- 2021-0201-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-15
- Subjects:
- Bioaerosols -- Improper operation -- High-risk region -- BSL-3 laboratory -- Risk assessment
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2021.107974 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17335.xml