Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams. (July 2021)
- Record Type:
- Journal Article
- Title:
- Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams. (July 2021)
- Main Title:
- Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams
- Authors:
- Holm, Kim Marina
Yukihara, Eduardo G.
Ahmed, Md Foiez
Greilich, Steffen
Jäkel, Oliver - Abstract:
- Highlights: Good applicability of triple channel analysis for 12 C-irradiated EBT3 film specimens. Corrected film signal shows considerably improved image quality. Quantitative agreement of corrected film signal with simultaneously IC measured data. Maximum deviation in a 12 C field reduced by a factor of 3 with triple channel analysis. Possible applications of EBT3 for QA measurements in 12 C beams. Abstract: Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for Gafchromic TM EBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of filmHighlights: Good applicability of triple channel analysis for 12 C-irradiated EBT3 film specimens. Corrected film signal shows considerably improved image quality. Quantitative agreement of corrected film signal with simultaneously IC measured data. Maximum deviation in a 12 C field reduced by a factor of 3 with triple channel analysis. Possible applications of EBT3 for QA measurements in 12 C beams. Abstract: Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for Gafchromic TM EBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of film artifacts. The corrected film signal showed considerably improved image quality and quantitative agreement with the ionization chamber data, thus providing a clear rationale for the usage of the triple channel analysis in carbon-beam QA. … (more)
- Is Part Of:
- Physica medica. Volume 87(2021)
- Journal:
- Physica medica
- Issue:
- Volume 87(2021)
- Issue Display:
- Volume 87, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 87
- Issue:
- 2021
- Issue Sort Value:
- 2021-0087-2021-0000
- Page Start:
- 123
- Page End:
- 130
- Publication Date:
- 2021-07
- Subjects:
- Triple channel analysis -- Gafchromic EBT3 -- Carbon-ion beams
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.06.009 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17324.xml