Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection. (June 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection. (June 2021)
- Main Title:
- Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection
- Authors:
- Inaba, Masato
Higashimoto, Yuki
Toyama, Yoko
Horiguchi, Tomoya
Hibino, Masaya
Iwata, Mitsunaga
Imaizumi, Kazuyoshi
Doi, Yohei - Abstract:
- Highlights: We compared sensitivities and specificities of the SARS-CoV-2 RT-LAMP with RT-qPCR. Up to the 9th day of onset, RT-LAMP has the same diagnostic sensitivity as RT-qPCR. After the 10th day of onset, the positivity of RT-LAMP decreased considerably. The limit of detection of RT-LAMP was 6.7 SARS-CoV-2 RNA copies/reaction. Abstract: Objective: Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been validated to diagnose several viral infections. However, its diagnostic accuracy in detecting SARS-CoV-2 in real-life clinical settings remains unclear. This study aimed to determine the diagnostic sensitivity and specificity of RT-LAMP compared to reverse transcription-quantitative polymerase chain reaction (RT-qPCR) over the disease course of COVID-19. Methods: A total of 124 nasopharyngeal swab samples obtained from 24 COVID-19 patients were tested by RT-LAMP and RT-qPCR. Sensitivities and specificities of RT-LAMP compared with RT-qPCR were analyzed as a function of time from onset. Results: Up to the 9th day after onset, the RT-LAMP had a positivity of 92.8%, and the sensitivity and specificity compared with RT-qPCR was 100%. However, after the 10th day after onset, the positivity of RT-LAMP decreased to less than 25%, and the concordance of positivity between the two methods was below 60%. The limit of detection of RT-LAMP was 6.7 copies/reaction. Conclusions: Until the 9th day after the onset of symptoms, RT-LAMP had the same diagnosticHighlights: We compared sensitivities and specificities of the SARS-CoV-2 RT-LAMP with RT-qPCR. Up to the 9th day of onset, RT-LAMP has the same diagnostic sensitivity as RT-qPCR. After the 10th day of onset, the positivity of RT-LAMP decreased considerably. The limit of detection of RT-LAMP was 6.7 SARS-CoV-2 RNA copies/reaction. Abstract: Objective: Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been validated to diagnose several viral infections. However, its diagnostic accuracy in detecting SARS-CoV-2 in real-life clinical settings remains unclear. This study aimed to determine the diagnostic sensitivity and specificity of RT-LAMP compared to reverse transcription-quantitative polymerase chain reaction (RT-qPCR) over the disease course of COVID-19. Methods: A total of 124 nasopharyngeal swab samples obtained from 24 COVID-19 patients were tested by RT-LAMP and RT-qPCR. Sensitivities and specificities of RT-LAMP compared with RT-qPCR were analyzed as a function of time from onset. Results: Up to the 9th day after onset, the RT-LAMP had a positivity of 92.8%, and the sensitivity and specificity compared with RT-qPCR was 100%. However, after the 10th day after onset, the positivity of RT-LAMP decreased to less than 25%, and the concordance of positivity between the two methods was below 60%. The limit of detection of RT-LAMP was 6.7 copies/reaction. Conclusions: Until the 9th day after the onset of symptoms, RT-LAMP had the same diagnostic accuracy as RT-qPCR. These findings suggest that RT-LAMP can be used as a diagnostic tool for COVID-19 as an alternative to RT-qPCR in the acute symptomatic phase of COVID-19. … (more)
- Is Part Of:
- International journal of infectious diseases. Volume 107(2021)
- Journal:
- International journal of infectious diseases
- Issue:
- Volume 107(2021)
- Issue Display:
- Volume 107, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 107
- Issue:
- 2021
- Issue Sort Value:
- 2021-0107-2021-0000
- Page Start:
- 195
- Page End:
- 200
- Publication Date:
- 2021-06
- Subjects:
- RT-LAMP -- RT-qPCR -- Sensitivity -- Specificity -- COVID-19
Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
Electronic journals
616.9 - Journal URLs:
- http://bibpurl.oclc.org/web/73769 ↗
http://www.journals.elsevier.com/international-journal-of-infectious-diseases/ ↗
http://www.sciencedirect.com/science/journal/12019712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/12019712 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/12019712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijid.2021.04.018 ↗
- Languages:
- English
- ISSNs:
- 1201-9712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.304750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17322.xml