Are Aneurysms Treated With Balloon-Assisted Coiling and Stent-Assisted Coiling Different? Morphological Analysis of 113 Unruptured Wide-Necked Aneurysms Treated With Adjunctive Devices. Issue 2 (15th April 2014)
- Record Type:
- Journal Article
- Title:
- Are Aneurysms Treated With Balloon-Assisted Coiling and Stent-Assisted Coiling Different? Morphological Analysis of 113 Unruptured Wide-Necked Aneurysms Treated With Adjunctive Devices. Issue 2 (15th April 2014)
- Main Title:
- Are Aneurysms Treated With Balloon-Assisted Coiling and Stent-Assisted Coiling Different? Morphological Analysis of 113 Unruptured Wide-Necked Aneurysms Treated With Adjunctive Devices
- Authors:
- Peterson, Eric
Hanak, Brian
Morton, Ryan
Osbun, Joshua W.
Levitt, Michael R.
Kim, Louis J. - Abstract:
- Abstract: BACKGROUND: In the endovascular treatment of wide-necked unruptured aneurysms, there is controversy over which adjunctive device (stent vs balloon) is appropriate. At the payer level it has been posited that stents and balloons treat the same aneurysms, and, as such, the more expensive stents should not be reimbursed. OBJECTIVE: We challenge this assertion, and instead hypothesize that aneurysms treated with stent assistance are morphologically different than those selected for balloon assistance. METHODS: Retrospective review of unruptured aneurysms treated with an adjunctive device between 2008 and 2010. Morphological analysis was performed on the pretreatment 2-D catheter angiogram. The immediate posttreatment Raymond score was compared with that seen on the 12-month follow-up angiogram. RESULTS: One hundred six unruptured aneurysms were treated with an adjunctive device and followed for a mean of 24.5 months. Morphological analysis revealed a lower dome-to-neck ratio (1.5 vs 1.2) and aspect ratio (1.44 vs 1.16) in the aneurysms treated with stent assistance vs balloon assistance. Of the 15.3% that were worse on follow-up angiography, there was no statistical difference between those treated with a stent vs a balloon (17.1% vs 14.2%). The overall re-treatment rate was 10.2% and was not statistically different between the 2 groups (12.7% vs 5.7%). CONCLUSION: We found that unruptured aneurysms selected for treatment with stent-assisted coiling are morphologicallyAbstract: BACKGROUND: In the endovascular treatment of wide-necked unruptured aneurysms, there is controversy over which adjunctive device (stent vs balloon) is appropriate. At the payer level it has been posited that stents and balloons treat the same aneurysms, and, as such, the more expensive stents should not be reimbursed. OBJECTIVE: We challenge this assertion, and instead hypothesize that aneurysms treated with stent assistance are morphologically different than those selected for balloon assistance. METHODS: Retrospective review of unruptured aneurysms treated with an adjunctive device between 2008 and 2010. Morphological analysis was performed on the pretreatment 2-D catheter angiogram. The immediate posttreatment Raymond score was compared with that seen on the 12-month follow-up angiogram. RESULTS: One hundred six unruptured aneurysms were treated with an adjunctive device and followed for a mean of 24.5 months. Morphological analysis revealed a lower dome-to-neck ratio (1.5 vs 1.2) and aspect ratio (1.44 vs 1.16) in the aneurysms treated with stent assistance vs balloon assistance. Of the 15.3% that were worse on follow-up angiography, there was no statistical difference between those treated with a stent vs a balloon (17.1% vs 14.2%). The overall re-treatment rate was 10.2% and was not statistically different between the 2 groups (12.7% vs 5.7%). CONCLUSION: We found that unruptured aneurysms selected for treatment with stent-assisted coiling are morphologically different from those selected for treatment with balloon assistance. Despite the more challenging morphology, Raymond scores and re-treatment rates at 1 year were not statistically different between the 2 groups, suggesting an important role for stents in the treatment of unruptured aneurysms. … (more)
- Is Part Of:
- Neurosurgery. Volume 75:Issue 2(2014)
- Journal:
- Neurosurgery
- Issue:
- Volume 75:Issue 2(2014)
- Issue Display:
- Volume 75, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 75
- Issue:
- 2
- Issue Sort Value:
- 2014-0075-0002-0000
- Page Start:
- 145
- Page End:
- 151
- Publication Date:
- 2014-04-15
- Subjects:
- Balloon assistance -- Endovascular -- Morphological analysis -- Stent assistance -- Unruptured aneurysm
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1227/NEU.0000000000000366 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17311.xml