Ablation index‐guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study. (13th October 2019)
- Record Type:
- Journal Article
- Title:
- Ablation index‐guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study. (13th October 2019)
- Main Title:
- Ablation index‐guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
- Authors:
- Chen, Shaojie
Schmidt, Boris
Bordignon, Stefano
Urbanek, Lukas
Tohoku, Shota
Bologna, Fabrizio
Angelkov, Lazar
Garvanski, Iskren
Tsianakas, Nikolaos
Konstantinou, Athanasios
Trolese, Luca
Weise, Felix
Perrotta, Laura
Chun, K. R. Julian - Abstract:
- Abstract: Background: Radiofrequency high‐power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI). Objectives: This study aimed to report the procedural data and initial results of a combined ablation technique using AI‐guided high‐power (AI‐HP; 50 W) ablation for PVI. Methods: Symptomatic AF patients were consecutively enrolled and underwent wide‐area contiguous circumferential PVI. Contact‐force catheters were used, ablation power was set to 50 W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy. Results: PVI was achieved in all (n = 50, mean age: 68 ± 9 years, female: 60%) patients, rate of first‐round PVI was 92%. A total of N = 2105 AI‐guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5 ± 8 vs 8.6 ± 3 and 12.2 ± 4 vs 9.3 ± 3; mean contact force (g): 17.1 ± 12 vs 25.4 ± 14 and 33.7 ± 13 vs 21.0 ± 11; mean AI: 547 ± 48 vs 445 ± 55 and 555 ± 56 vs 440 ± 47 (all P < .0001). Procedure and fluoroscopy time (minute) were 55.6 ± 6.6 and 6 ± 1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In‐hospital and 1‐month follow‐up no major complications such as death, stroke, tamponade, orAbstract: Background: Radiofrequency high‐power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI). Objectives: This study aimed to report the procedural data and initial results of a combined ablation technique using AI‐guided high‐power (AI‐HP; 50 W) ablation for PVI. Methods: Symptomatic AF patients were consecutively enrolled and underwent wide‐area contiguous circumferential PVI. Contact‐force catheters were used, ablation power was set to 50 W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy. Results: PVI was achieved in all (n = 50, mean age: 68 ± 9 years, female: 60%) patients, rate of first‐round PVI was 92%. A total of N = 2105 AI‐guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5 ± 8 vs 8.6 ± 3 and 12.2 ± 4 vs 9.3 ± 3; mean contact force (g): 17.1 ± 12 vs 25.4 ± 14 and 33.7 ± 13 vs 21.0 ± 11; mean AI: 547 ± 48 vs 445 ± 55 and 555 ± 56 vs 440 ± 47 (all P < .0001). Procedure and fluoroscopy time (minute) were 55.6 ± 6.6 and 6 ± 1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In‐hospital and 1‐month follow‐up no major complications such as death, stroke, tamponade, or atriaesophageal fistula (AE) occurred. Preliminary 6‐month follow‐up showed 48 of 50 (96%) patients were free from clinical AF/atrial tachycardia recurrence. Conclusion: AI‐HP (50 W) ablation appears to be a feasible, safe, fast, and effective ablation technique for PVI. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 12(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 12(2019)
- Issue Display:
- Volume 30, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 12
- Issue Sort Value:
- 2019-0030-0012-0000
- Page Start:
- 2724
- Page End:
- 2731
- Publication Date:
- 2019-10-13
- Subjects:
- ablation -- ablation index -- atrial fibrillation -- high power -- pulmonary vein isolation
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14219 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17312.xml