Diagnostic accuracy of coronary opacification derived from coronary computed tomography angiography to detect ischemia: first validation versus single-photon emission computed tomography. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of coronary opacification derived from coronary computed tomography angiography to detect ischemia: first validation versus single-photon emission computed tomography. Issue 1 (December 2017)
- Main Title:
- Diagnostic accuracy of coronary opacification derived from coronary computed tomography angiography to detect ischemia: first validation versus single-photon emission computed tomography
- Authors:
- Benz, Dominik
Mikulicic, Fran
Gräni, Christoph
Grossmann, Marvin
Giannopoulos, Andreas
Messerli, Michael
Gebhard, Catherine
Gaemperli, Oliver
Buechel, Ronny
Kaufmann, Philipp
Pazhenkottil, Aju - Abstract:
- Abstract Background Estimation of functional relevance of a coronary stenosis by fractional flow reserve (FFR) from coronary computed tomography angiography (CCTA) has recently provided encouraging results. Due to its limited availability, the corrected contrast opacification (CCO) decrease and the transluminal attenuation gradient (TAG) were suggested as less complex alternatives. The aim of the present study was to assess the accuracy of CCO decrease and TAG to predict ischemia as assessed by single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Results This retrospective study included 72 patients who underwent hybrid CCTA/SPECT MPI with at least one coronary artery stenosis. Of 127 vessels with a coronary stenosis in CCTA, 38 (30%) were causing ischemia in its subtending myocardium. The area under the curve (AUC) for CCO decrease to predict ischemia was 0.707 with sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of 74, 64, 85, 47, and 67%, respectively. For TAG, the AUC was 0.469. Conclusions CCTA-derived CCO decrease but not TAG predicts ischemia in SPECT MPI. The negative predictive value of CCO decrease of 85% may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.
- Is Part Of:
- EJNMMI research. Volume 7:Issue 1(2017)
- Journal:
- EJNMMI research
- Issue:
- Volume 7:Issue 1(2017)
- Issue Display:
- Volume 7, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2017-0007-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2017-12
- Subjects:
- CT-derived functional parameters -- CCO decrease -- Corrected contrast opacification -- Transluminal attenuation gradient -- TAG
Nuclear medicine -- Periodicals
Molecular probes -- Periodicals
Diagnostic imaging -- Periodicals
Radioimmunoimaging -- Periodicals
616.07575 - Journal URLs:
- http://www.ejnmmires.com/ ↗
http://www.springerlink.com/content/2191-219X ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1186/s13550-017-0342-8 ↗
- Languages:
- English
- ISSNs:
- 2191-219X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3668.429000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17310.xml