A nurse‐led implantable loop recorder service is safe and cost effective. (9th October 2019)
- Record Type:
- Journal Article
- Title:
- A nurse‐led implantable loop recorder service is safe and cost effective. (9th October 2019)
- Main Title:
- A nurse‐led implantable loop recorder service is safe and cost effective
- Authors:
- Lim, Wei Yao
Papageorgiou, Nikolaos
Sukumar, Shivasankar M.
Alexiou, Sophia
Srinivasan, Neil T.
Monkhouse, Christopher
Daw, Holly
Caldeira, Helder
Harvie, Helen
Kuriakose, Jincymol
Baca, Marco
Ahsan, Syed Y.
Chow, Anthony W.
Hunter, Ross J.
Finlay, Malcolm
Lambiase, Pier D.
Schilling, Richard J.
Earley, Mark J.
Providencia, Rui - Abstract:
- Abstract: Introduction: Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse‐delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost‐effectiveness of the introduction of this nurse‐delivered ILR service with contemporaneous physician‐led procedures. Methods: Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed. Results: A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician‐implants and two in nurse‐implants ( P = .3). Procedural time for physician‐implants (13.4 ± 8.0 minutes) and nurse‐implants (14.2 ± 10.1 minutes) were comparable ( P = .98). The procedural cost was estimated as £576.02 for physician‐implants against £279.95 with nurse‐implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse‐delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse‐delivered model forAbstract: Introduction: Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse‐delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost‐effectiveness of the introduction of this nurse‐delivered ILR service with contemporaneous physician‐led procedures. Methods: Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed. Results: A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician‐implants and two in nurse‐implants ( P = .3). Procedural time for physician‐implants (13.4 ± 8.0 minutes) and nurse‐implants (14.2 ± 10.1 minutes) were comparable ( P = .98). The procedural cost was estimated as £576.02 for physician‐implants against £279.95 with nurse‐implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse‐delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse‐delivered model for ILR implants. Over 133 catheter laboratory and implanting physician hours were saved and utilized for other more complex procedures. Conclusion: ILR implantation in the outpatient setting by suitably trained nurses is safe and leads to significant financial savings. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 12(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 12(2019)
- Issue Display:
- Volume 30, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 12
- Issue Sort Value:
- 2019-0030-0012-0000
- Page Start:
- 2900
- Page End:
- 2906
- Publication Date:
- 2019-10-09
- Subjects:
- arrhythmias -- implantable loop recorder -- syncope
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14206 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17309.xml