A randomized comparison of manual pressure versus figure‐of‐eight suture for hemostasis after cryoballoon ablation for atrial fibrillation. (14th November 2019)
- Record Type:
- Journal Article
- Title:
- A randomized comparison of manual pressure versus figure‐of‐eight suture for hemostasis after cryoballoon ablation for atrial fibrillation. (14th November 2019)
- Main Title:
- A randomized comparison of manual pressure versus figure‐of‐eight suture for hemostasis after cryoballoon ablation for atrial fibrillation
- Authors:
- Kumar, Vineet
Wish, Marc
Venkataraman, Ganesh
Bliden, Kevin
Jindal, Manila
Strickberger, Adam - Abstract:
- Abstract: Introduction: Cryoballoon ablation is commonly used to treat atrial fibrillation (AF). Femoral vein hemostasis after cryoballoon ablation for AF is routinely achieved with manual pressure (MP) after reversal of heparin and reassessment of the activated clotting time, or with a figure‐of‐eight suture (F8). The purpose of this randomized trial was to compare these two techniques for femoral vein hemostasis after cryoballoon ablation for AF in a patient population predominantly on novel anticoagulants (NOAC). Methods and Results: Seventy consecutive patients who underwent cryoballoon ablation were randomized to either the MP or F8 for femoral vein hemostasis. Clinical and procedural characteristics were similar between the groups with the majority of patients treated with a NOAC. The total time in the electrophysiology laboratory for the MP group and the F8 group (197 ± 37 minutes vs 167 ± 36 minutes, respectively; P = .02), and the time from sheath removal until the patient left the laboratory (28 ± 9 minutes vs 20 ± 5 minutes, respectively; P < .0001) were significantly less in the F8 group. Additional pressure for hemostasis in the recovery suite was required more often in the MP Group, as opposed to the F8 group (29% vs 3%; P = .003). No major bleeding occurred and the rate of minor hematomas was statistically similar. Conclusions: Hemostasis obtained with a F8 suture after cryoballoon ablation for AF is associated with significantly less patient time in theAbstract: Introduction: Cryoballoon ablation is commonly used to treat atrial fibrillation (AF). Femoral vein hemostasis after cryoballoon ablation for AF is routinely achieved with manual pressure (MP) after reversal of heparin and reassessment of the activated clotting time, or with a figure‐of‐eight suture (F8). The purpose of this randomized trial was to compare these two techniques for femoral vein hemostasis after cryoballoon ablation for AF in a patient population predominantly on novel anticoagulants (NOAC). Methods and Results: Seventy consecutive patients who underwent cryoballoon ablation were randomized to either the MP or F8 for femoral vein hemostasis. Clinical and procedural characteristics were similar between the groups with the majority of patients treated with a NOAC. The total time in the electrophysiology laboratory for the MP group and the F8 group (197 ± 37 minutes vs 167 ± 36 minutes, respectively; P = .02), and the time from sheath removal until the patient left the laboratory (28 ± 9 minutes vs 20 ± 5 minutes, respectively; P < .0001) were significantly less in the F8 group. Additional pressure for hemostasis in the recovery suite was required more often in the MP Group, as opposed to the F8 group (29% vs 3%; P = .003). No major bleeding occurred and the rate of minor hematomas was statistically similar. Conclusions: Hemostasis obtained with a F8 suture after cryoballoon ablation for AF is associated with significantly less patient time in the electrophysiology laboratory, and an improved safety profile, compared with manual hemostasis, even amongst patients treated with a NOAC. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 12(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 12(2019)
- Issue Display:
- Volume 30, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 12
- Issue Sort Value:
- 2019-0030-0012-0000
- Page Start:
- 2806
- Page End:
- 2810
- Publication Date:
- 2019-11-14
- Subjects:
- atrial fibrillation -- atrial fibrillation ablation -- cryoballoon -- figure‐of‐eight suture -- hemostasis -- manual pressure
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14252 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17309.xml