Prediction of Remnant Liver Regeneration after Right Hepatectomy in Patients with Hepatocellular Carcinoma Using Preoperative CT Texture Analysis and Clinical Features. (11th June 2021)
- Record Type:
- Journal Article
- Title:
- Prediction of Remnant Liver Regeneration after Right Hepatectomy in Patients with Hepatocellular Carcinoma Using Preoperative CT Texture Analysis and Clinical Features. (11th June 2021)
- Main Title:
- Prediction of Remnant Liver Regeneration after Right Hepatectomy in Patients with Hepatocellular Carcinoma Using Preoperative CT Texture Analysis and Clinical Features
- Authors:
- Zhang, Tong
Wei, Yi
He, Xiaopeng
Yuan, Yuan
Yuan, Fang
Ye, Zheng
Li, Xin
Tang, Hehan
Song, Bin - Other Names:
- Filippi Luca Academic Editor.
- Abstract:
- Abstract : Objectives . To predict the regenerative rate of liver in patients with HCCs after right hepatectomy using texture analysis on preoperative CT combined with clinical features. Materials and Methods . 88 patients with 90 HCCs who underwent right hepatectomy were retrospectively included. The future remnant liver was semiautomatically segmented, and the volume of future remnant liver on preoperative CT (LVpre ) and the volume of remnant liver on following-up CT (LVfu ) were measured. We calculated the regeneration index (RI) by the following equation: (LVfu – LVpre )/LVpre ) × 100 (%). The support vector machine recursive method was used for the feature selection. The Naive Bayes classifier was used to predict liver RI, and 5-fold cross-validation was performed to adjust the parameters. Sensitivity, specificity, and accuracy were calculated to evaluate the diagnostic efficiency of the model. Results . The mean RI was 142.99 ± 92.17%. Of all clinical parameters and texture features, the AST, ALB, PT-INR, Perc.10%, and S(5, −5)Correlat were found to be statistically significant with RI. The diagnostic sensitivity, specificity, and accuracy of the model in the training group were 0.902, 0.634, and 0.768, and the AUC value of the obtained model was 0.841. In the test group, the sensitivity, specificity, and accuracy of the model were 1.0, 0.429, and 0.778, respectively, and the AUC value was 0.844. Conclusion . The use of texture analysis on preoperative CT combinedAbstract : Objectives . To predict the regenerative rate of liver in patients with HCCs after right hepatectomy using texture analysis on preoperative CT combined with clinical features. Materials and Methods . 88 patients with 90 HCCs who underwent right hepatectomy were retrospectively included. The future remnant liver was semiautomatically segmented, and the volume of future remnant liver on preoperative CT (LVpre ) and the volume of remnant liver on following-up CT (LVfu ) were measured. We calculated the regeneration index (RI) by the following equation: (LVfu – LVpre )/LVpre ) × 100 (%). The support vector machine recursive method was used for the feature selection. The Naive Bayes classifier was used to predict liver RI, and 5-fold cross-validation was performed to adjust the parameters. Sensitivity, specificity, and accuracy were calculated to evaluate the diagnostic efficiency of the model. Results . The mean RI was 142.99 ± 92.17%. Of all clinical parameters and texture features, the AST, ALB, PT-INR, Perc.10%, and S(5, −5)Correlat were found to be statistically significant with RI. The diagnostic sensitivity, specificity, and accuracy of the model in the training group were 0.902, 0.634, and 0.768, and the AUC value of the obtained model was 0.841. In the test group, the sensitivity, specificity, and accuracy of the model were 1.0, 0.429, and 0.778, respectively, and the AUC value was 0.844. Conclusion . The use of texture analysis on preoperative CT combined with clinical features can be helpful in predicting the liver regeneration rate in patients with HCCs after right hepatectomy. … (more)
- Is Part Of:
- Contrast media & molecular imaging. Volume 2021(2021)
- Journal:
- Contrast media & molecular imaging
- Issue:
- Volume 2021(2021)
- Issue Display:
- Volume 2021, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 2021
- Issue:
- 2021
- Issue Sort Value:
- 2021-2021-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06-11
- Subjects:
- Diagnostic imaging -- Periodicals
Magnetic resonance imaging -- Periodicals
Contrast media (Diagnostic imaging) -- Periodicals
Contrast Media -- Periodicals
Diagnostic Imaging -- Periodicals
Substances de contraste -- Périodiques
Diagnostics moléculaires -- Périodiques
Imagerie médicale
Substance de contraste
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.0754 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/15554317 ↗
https://www.hindawi.com/journals/cmmi/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1155/2021/5572470 ↗
- Languages:
- English
- ISSNs:
- 1555-4309
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3426.351450
British Library HMNTS - ELD Digital store - Ingest File:
- 17300.xml