Rigid and non-rigid geometrical transformations of a marker-cluster and their impact on bone-pose estimation. Issue 15 (26th November 2015)
- Record Type:
- Journal Article
- Title:
- Rigid and non-rigid geometrical transformations of a marker-cluster and their impact on bone-pose estimation. Issue 15 (26th November 2015)
- Main Title:
- Rigid and non-rigid geometrical transformations of a marker-cluster and their impact on bone-pose estimation
- Authors:
- Bonci, T.
Camomilla, V.
Dumas, R.
Chèze, L.
Cappozzo, A. - Abstract:
- Abstract: When stereophotogrammetry and skin-markers are used, bone-pose estimation is jeopardised by the soft tissue artefact (STA). At marker-cluster level, this can be represented using a modal series of rigid (RT; translation and rotation) and non-rigid (NRT; homothety and scaling) geometrical transformations. The NRT has been found to be smaller than the RT and claimed to have a limited impact on bone-pose estimation. This study aims to investigate this matter and comparatively assessing the propagation of both STA components to bone-pose estimate, using different numbers of markers. Twelve skin-markers distributed over the anterior aspect of a thigh were considered and STA time functions were generated for each of them, as plausibly occurs during walking, using an ad hoc model and represented through the geometrical transformations. Using marker-clusters made of four to 12 markers affected by these STAs, and a Procrustes superimposition approach, bone-pose and the relevant accuracy were estimated. This was done also for a selected four marker-cluster affected by STAs randomly simulated by modifying the original STA NRT component, so that its energy fell in the range 30–90% of total STA energy. The pose error, which slightly decreased while increasing the number of markers in the marker-cluster, was independent from the NRT amplitude, and was always null when the RT component was removed. It was thus demonstrated that only the RT component impacts pose estimationAbstract: When stereophotogrammetry and skin-markers are used, bone-pose estimation is jeopardised by the soft tissue artefact (STA). At marker-cluster level, this can be represented using a modal series of rigid (RT; translation and rotation) and non-rigid (NRT; homothety and scaling) geometrical transformations. The NRT has been found to be smaller than the RT and claimed to have a limited impact on bone-pose estimation. This study aims to investigate this matter and comparatively assessing the propagation of both STA components to bone-pose estimate, using different numbers of markers. Twelve skin-markers distributed over the anterior aspect of a thigh were considered and STA time functions were generated for each of them, as plausibly occurs during walking, using an ad hoc model and represented through the geometrical transformations. Using marker-clusters made of four to 12 markers affected by these STAs, and a Procrustes superimposition approach, bone-pose and the relevant accuracy were estimated. This was done also for a selected four marker-cluster affected by STAs randomly simulated by modifying the original STA NRT component, so that its energy fell in the range 30–90% of total STA energy. The pose error, which slightly decreased while increasing the number of markers in the marker-cluster, was independent from the NRT amplitude, and was always null when the RT component was removed. It was thus demonstrated that only the RT component impacts pose estimation accuracy and should thus be accounted for when designing algorithms aimed at compensating for STA. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 48:Issue 15(2015)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 48:Issue 15(2015)
- Issue Display:
- Volume 48, Issue 15 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue:
- 15
- Issue Sort Value:
- 2015-0048-0015-0000
- Page Start:
- 4166
- Page End:
- 4172
- Publication Date:
- 2015-11-26
- Subjects:
- Human movement analysis -- Modelling -- Soft tissue artefact -- Soft tissue deformation -- Rigid motion
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2015.10.031 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17285.xml