- Evaluation of an automated chromogenic assay for Factor VIII clotting activity measurement in patients affected by haemophilia A
- Authors:
- Novembrino, Cristina
Boscolo Anzoletti, Massimo
Mancuso, Maria Elisa
Shinohara, Sho
Peyvandi, Flora - Abstract:
- Abstract : Introduction: The original one‐stage clotting assay is still the most widely used method to measure Factor VIII clotting activity (FVIII:C) in patients with haemophilia A (HA), although the use of chromogenic assays is increasing significantly. Aim: Evaluation of the analytical performance and diagnostic accuracy of BIOPHEN™ FVIII:C (HYPHEN BioMed, Neuville‐sur‐Oise, France) assay on Sysmex CS‐2400 (Sysmex, Kobe, Japan) analyser. Methods: Sixty patients with haemophilia A (HA; any severity) and 120 healthy Italian subjects were included. All the assays were performed on citrate platelet‐poor plasmas stored at −80°C. Chromogenic BIOPHEN™ FVIII:C was compared with the one‐stage assay using Actin FS and Factor VIII deficient plasma (Siemens Healthcare Diagnostics, Marburg, Germany) on Sysmex CS‐2400 and with another chromogenic automated assay (COAMATIC™ Factor VIII, CHROMOGENIX on ACL TOP analyzer; Instrumentation Laboratory, Milan, Italy). Results: Intra‐assay and inter‐assay coefficient of variation were <6%. Linearity was good up to 1/128 dilution ( r = 0.99); mean recovery was 91.7% and limit of detection was 0.2%. BIOPHEN™ FVIII:C assay showed a good correlation and diagnostic agreement with the chromogenic COAMATIC™ assay: the Spearmen's Rank correlation coefficient was 0.98 and the inter‐rate agreement K Cohen coefficient was 0.61. The K coefficient was 0.91 when BIOPHEN™ FVIII:C was compared with the historical classification of the patients, demonstratingAbstract : Introduction: The original one‐stage clotting assay is still the most widely used method to measure Factor VIII clotting activity (FVIII:C) in patients with haemophilia A (HA), although the use of chromogenic assays is increasing significantly. Aim: Evaluation of the analytical performance and diagnostic accuracy of BIOPHEN™ FVIII:C (HYPHEN BioMed, Neuville‐sur‐Oise, France) assay on Sysmex CS‐2400 (Sysmex, Kobe, Japan) analyser. Methods: Sixty patients with haemophilia A (HA; any severity) and 120 healthy Italian subjects were included. All the assays were performed on citrate platelet‐poor plasmas stored at −80°C. Chromogenic BIOPHEN™ FVIII:C was compared with the one‐stage assay using Actin FS and Factor VIII deficient plasma (Siemens Healthcare Diagnostics, Marburg, Germany) on Sysmex CS‐2400 and with another chromogenic automated assay (COAMATIC™ Factor VIII, CHROMOGENIX on ACL TOP analyzer; Instrumentation Laboratory, Milan, Italy). Results: Intra‐assay and inter‐assay coefficient of variation were <6%. Linearity was good up to 1/128 dilution ( r = 0.99); mean recovery was 91.7% and limit of detection was 0.2%. BIOPHEN™ FVIII:C assay showed a good correlation and diagnostic agreement with the chromogenic COAMATIC™ assay: the Spearmen's Rank correlation coefficient was 0.98 and the inter‐rate agreement K Cohen coefficient was 0.61. The K coefficient was 0.91 when BIOPHEN™ FVIII:C was compared with the historical classification of the patients, demonstrating an optimal diagnostic accuracy in HA. Conclusions: BIOPHEN™ FVIII:C showed good analytical performance and diagnostic accuracy and could be considered suitable for the introduction in routine analytical panel of coagulation for the diagnosis of HA patients. … (more)
- Is Part Of:
- Haemophilia. Volume 25:Issue 3(2019)
- Journal:
- Haemophilia
- Issue:
- Volume 25:Issue 3(2019)
- Issue Display:
- Volume 25, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2019-0025-0003-0000
- Page Start:
- 521
- Page End:
- 526
- Publication Date:
- 2019-05-02
- Subjects:
- analytical performance -- chromogenic assay -- diagnostic accuracy -- Factor VIII -- haemophilia A
Hemophilia -- Periodicals
616.1572005 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=hae ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2516 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/hae.13746 ↗
- Languages:
- English
- ISSNs:
- 1351-8216
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4238.086500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17286.xml