Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta: Noninvasive evaluation using phase contrast magnetic resonance imaging. Issue 2 (February 2020)
- Record Type:
- Journal Article
- Title:
- Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta: Noninvasive evaluation using phase contrast magnetic resonance imaging. Issue 2 (February 2020)
- Main Title:
- Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta
- Authors:
- Izawa, Yoshimitsu
Hishikawa, Shuji
Matsumura, Yosuke
Nakamura, Hiroyasu
Sugimoto, Hideharu
Mato, Takashi - Abstract:
- Abstract : BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a viable resuscitation approach for a subdiaphragmatic injury that can regulate arterial blood flow. On the other hand, the evaluation of venous or portal venous blood flow during REBOA remains insufficient because invasive cannulation or exposure of the vessel may affect the blood flow, and Doppler echography is highly operator-dependent. However, phase contrast magnetic resonance imaging has enabled accurate evaluation and noninvasive measurement. This study aimed to investigate the change of venous and portal venous blood flow during REBOA in a porcine model. METHODS: Seven pigs were anesthetized, and a REBOA catheter was placed. The blood flows of the inferior vena cava (IVC), hepatic vein (HV), portal vein (PV), and superior vena cava (SVC) were measured using phase contrast magnetic resonance imaging, in both the balloon deflated (no-REBOA) and fully balloon inflated (REBOA) states. Mean arterial pressure (MAP), central venous pressure, cardiac index, and systemic vascular resistance index were measured. RESULTS: The blood flows of the suprahepatic, infrahepatic, and distal IVC, HV, and PV in the no-REBOA state were 1.40 ± 0.36 L·min −1, 0.94 ± 0.16 L·min −1, 0.50 ± 0.19 L·min −1, 0.060 ± 0.018 L·min −1, and 0.32 ± 0.091 L·min −1, respectively. The blood flow of each section in the REBOA condition was significantly decreased at 0.41 ± 0.078 (33% of baseline), 0.15 ± 0.13 (15%),Abstract : BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a viable resuscitation approach for a subdiaphragmatic injury that can regulate arterial blood flow. On the other hand, the evaluation of venous or portal venous blood flow during REBOA remains insufficient because invasive cannulation or exposure of the vessel may affect the blood flow, and Doppler echography is highly operator-dependent. However, phase contrast magnetic resonance imaging has enabled accurate evaluation and noninvasive measurement. This study aimed to investigate the change of venous and portal venous blood flow during REBOA in a porcine model. METHODS: Seven pigs were anesthetized, and a REBOA catheter was placed. The blood flows of the inferior vena cava (IVC), hepatic vein (HV), portal vein (PV), and superior vena cava (SVC) were measured using phase contrast magnetic resonance imaging, in both the balloon deflated (no-REBOA) and fully balloon inflated (REBOA) states. Mean arterial pressure (MAP), central venous pressure, cardiac index, and systemic vascular resistance index were measured. RESULTS: The blood flows of the suprahepatic, infrahepatic, and distal IVC, HV, and PV in the no-REBOA state were 1.40 ± 0.36 L·min −1, 0.94 ± 0.16 L·min −1, 0.50 ± 0.19 L·min −1, 0.060 ± 0.018 L·min −1, and 0.32 ± 0.091 L·min −1, respectively. The blood flow of each section in the REBOA condition was significantly decreased at 0.41 ± 0.078 (33% of baseline), 0.15 ± 0.13 (15%), 0.043 ± 0.034 (9%), 0.029 ± 0.017 (37%), and 0.070 ± 0.034 L·min −1 (21%), respectively. The blood flow of the SVC increased significantly in the REBOA condition (1.4 ± 0.63 L·min −1 vs. 0.53 ± 0.14 L·min −1 [257%]). Mean arterial pressure, central venous pressure, cardiac index, and systemic vascular resistance index were significantly increased after REBOA inflation. CONCLUSION: Resuscitative endovascular balloon occlusion of the aorta decreased blood flows of the IVC, HV, and PV and increased blood flow of the SVC. This result could be explained by the collateral flow from the lower body to the SVC. A better understanding of the effect of REBOA on the venous and portal venous systems may help control liver injury. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 88:Issue 2(2020)
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 88:Issue 2(2020)
- Issue Display:
- Volume 88, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 88
- Issue:
- 2
- Issue Sort Value:
- 2020-0088-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-02
- Subjects:
- REBOA -- phase contrast MRI -- venous hemodynamics
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000002557 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17282.xml