Contribution of diffusion-weighted MR imaging in follow-up of inflammatory appendiceal mass: Preliminary results and review of the literature. (2016)
- Record Type:
- Journal Article
- Title:
- Contribution of diffusion-weighted MR imaging in follow-up of inflammatory appendiceal mass: Preliminary results and review of the literature. (2016)
- Main Title:
- Contribution of diffusion-weighted MR imaging in follow-up of inflammatory appendiceal mass: Preliminary results and review of the literature
- Authors:
- Özdemir, Oğuzhan
Metin, Yavuz
Metin, Nurgül Orhan
Küpeli, Ali
Kalcan, Süleyman
Taşçı, Filiz - Abstract:
- Abstract: Objective: We aimed to search the contribution of diffusion-weighted imaging (DWI) in follow-up of patients with acute appendicitis associated inflammatory appendiceal mass (IAM). DWI was used as a monitoring imaging method to assess the response of medical treatment. Materials and methods: 19 patients (mean age, 37+–13.1; age range, 19–69; M/F: 10/9), presented with clinical, laboratory and computed tomography (CT) findings suggestive of IAM were enrolled prospectively in this study. CT and DWI images were evaluated by two radiologists in consensus. b values 0, 500 and 1000 s/mm 2 were used, and DWI images were analysed both qualitatively and quantitatively. Laboratory parameters were C-reactive protein value and white blood cell count. During follow-up changes in the diameter of IMA and laboratory parameters were correlated with ADC values. Conservative treatment with interval appendectomy and a total conservative approach without surgery were the treatment options during follow-up. Results: We found statistically significant correlation between the ADC values, maximum IAM diameter and laboratory parameters. During follow-up five surgical procedures were performed: one patient underwent surgery for cecal adenocarcinoma and four underwent interval appendectomy. One patient developed acute relapse of IAM at the sixth month of follow-up. Conclusion: DWI may be used with a significant success for follow-up of patients with IAM. As a monitoring imaging method, DWI mayAbstract: Objective: We aimed to search the contribution of diffusion-weighted imaging (DWI) in follow-up of patients with acute appendicitis associated inflammatory appendiceal mass (IAM). DWI was used as a monitoring imaging method to assess the response of medical treatment. Materials and methods: 19 patients (mean age, 37+–13.1; age range, 19–69; M/F: 10/9), presented with clinical, laboratory and computed tomography (CT) findings suggestive of IAM were enrolled prospectively in this study. CT and DWI images were evaluated by two radiologists in consensus. b values 0, 500 and 1000 s/mm 2 were used, and DWI images were analysed both qualitatively and quantitatively. Laboratory parameters were C-reactive protein value and white blood cell count. During follow-up changes in the diameter of IMA and laboratory parameters were correlated with ADC values. Conservative treatment with interval appendectomy and a total conservative approach without surgery were the treatment options during follow-up. Results: We found statistically significant correlation between the ADC values, maximum IAM diameter and laboratory parameters. During follow-up five surgical procedures were performed: one patient underwent surgery for cecal adenocarcinoma and four underwent interval appendectomy. One patient developed acute relapse of IAM at the sixth month of follow-up. Conclusion: DWI may be used with a significant success for follow-up of patients with IAM. As a monitoring imaging method, DWI may also aid in determining of most appropriate timing for interval appendectomy as well as may help in diagnosing alternative diagnoses (e.g. malignancy and inflammatory bowel disease) that can mimic IAM. … (more)
- Is Part Of:
- European journal of radiology open. Volume 3(2016)
- Journal:
- European journal of radiology open
- Issue:
- Volume 3(2016)
- Issue Display:
- Volume 3, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 3
- Issue:
- 2016
- Issue Sort Value:
- 2016-0003-2016-0000
- Page Start:
- 207
- Page End:
- 215
- Publication Date:
- 2016
- Subjects:
- Inflammatory appendiceal mass -- Diffusion-weighted imaging
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2016.08.005 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17278.xml