Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging. (2016)
- Record Type:
- Journal Article
- Title:
- Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging. (2016)
- Main Title:
- Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging
- Authors:
- Nakamura, Yuko
Higaki, Toru
Akiyama, Yuji
Fukumoto, Wataru
Kajiwara, Kenji
Kaichi, Yoko
Honda, Yukiko
Komoto, Daisuke
Tatsugami, Fuminari
Iida, Makoto
Ohmoto, Toshifumi
Date, Shuji
Awai, Kazuo - Abstract:
- Abstract: Purpose: To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. Materials and methods: In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm 2 ) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm 2, TE 70 ms; b-value 0 and 600 s/mm 2, TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm 2 at 1.5T and 3T as "o-1.5T-1000" and "o-3T-1000". c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm 2 . c-DWI with b = 1000 and 1500 s/mm 2 were defined as "c-1000" and "c-1500". Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm 2 on 1.5T- and 3T DWIs. Results: Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm 2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm 2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Conclusions:Abstract: Purpose: To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. Materials and methods: In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm 2 ) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm 2, TE 70 ms; b-value 0 and 600 s/mm 2, TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm 2 at 1.5T and 3T as "o-1.5T-1000" and "o-3T-1000". c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm 2 . c-DWI with b = 1000 and 1500 s/mm 2 were defined as "c-1000" and "c-1500". Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm 2 on 1.5T- and 3T DWIs. Results: Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm 2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm 2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Conclusions: Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs. … (more)
- Is Part Of:
- European journal of radiology open. Volume 3(2016)
- Journal:
- European journal of radiology open
- Issue:
- Volume 3(2016)
- Issue Display:
- Volume 3, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 3
- Issue:
- 2016
- Issue Sort Value:
- 2016-0003-2016-0000
- Page Start:
- 138
- Page End:
- 144
- Publication Date:
- 2016
- Subjects:
- DWI diffusion-weighted imaging -- MRI magnetic resonance imaging -- SI signal intensity -- HCC hepatocellular carcinoma -- SNR signal-to-noise ratio -- c-DWI computed diffusion-weighted imaging -- T1-WI T1-weighted MRI -- T2-WI T2-weighted MRI -- ADC apparent diffusion coefficient -- CR contrast ratio
Diffusion-weighted imaging -- Field strength -- Computed diffusion-weighted imaging -- Non-complicated hepatic cysts -- T2 shine-through effect
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2016.07.001 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17278.xml