His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study. (2nd August 2019)
- Record Type:
- Journal Article
- Title:
- His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study. (2nd August 2019)
- Main Title:
- His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: Insights from a large international observational study
- Authors:
- Keene, Daniel
Arnold, Ahran D
Jastrzębski, Marek
Burri, Haran
Zweibel, Steven
Crespo, Eric
Chandrasekaran, Badrinathan
Bassi, Sukhbinder
Joghetaei, Nader
Swift, Matthew
Moskal, Pawel
Francis, Darrel P
Foley, Paul
Shun‐Shin, Matthew J
Whinnett, Zachary I - Abstract:
- Abstract: Background: His‐bundle pacing (HBP) provides physiological ventricular activation. Observational studies have demonstrated the techniques' feasibility; however, data have come from a limited number of centers. Objectives: We set out to explore the contemporary global practice in HBP focusing on the learning curve, procedural characteristics, and outcomes. Methods: This is a retrospective, multicenter observational study of patients undergoing attempted HBP at seven centers. Pacing indication, fluoroscopy time, HBP thresholds, and lead reintervention and deactivation rates were recorded. Where centers had systematically recorded implant success rates from the outset, these were collated. Results: A total of 529 patients underwent attempted HBP during the study period (2014‐19) with a mean follow‐up of 217 ± 303 days. Most implants were for bradycardia indications. In the three centers with the systematic collation of all attempts, the overall implant success rate was 81%, which improved to 87% after completion of 40 cases. All seven centers reported data on successful implants. The mean fluoroscopy time was 11.7 ± 12.0 minutes, the His‐bundle capture threshold at implant was 1.4 ± 0.9 V at 0.8 ± 0.3 ms, and it was 1.3 ± 1.2 V at 0.9 ± 0.2 ms at last device check. HBP lead reintervention or deactivation (for lead displacement or rise in threshold) occurred in 7.5% of successful implants. There was evidence of a learning curve: fluoroscopy time and HBP captureAbstract: Background: His‐bundle pacing (HBP) provides physiological ventricular activation. Observational studies have demonstrated the techniques' feasibility; however, data have come from a limited number of centers. Objectives: We set out to explore the contemporary global practice in HBP focusing on the learning curve, procedural characteristics, and outcomes. Methods: This is a retrospective, multicenter observational study of patients undergoing attempted HBP at seven centers. Pacing indication, fluoroscopy time, HBP thresholds, and lead reintervention and deactivation rates were recorded. Where centers had systematically recorded implant success rates from the outset, these were collated. Results: A total of 529 patients underwent attempted HBP during the study period (2014‐19) with a mean follow‐up of 217 ± 303 days. Most implants were for bradycardia indications. In the three centers with the systematic collation of all attempts, the overall implant success rate was 81%, which improved to 87% after completion of 40 cases. All seven centers reported data on successful implants. The mean fluoroscopy time was 11.7 ± 12.0 minutes, the His‐bundle capture threshold at implant was 1.4 ± 0.9 V at 0.8 ± 0.3 ms, and it was 1.3 ± 1.2 V at 0.9 ± 0.2 ms at last device check. HBP lead reintervention or deactivation (for lead displacement or rise in threshold) occurred in 7.5% of successful implants. There was evidence of a learning curve: fluoroscopy time and HBP capture threshold reduced with greater experience, plateauing after approximately 30‐50 cases. Conclusion: We found that it is feasible to establish a successful HBP program, using the currently available implantation tools. For physicians who are experienced at pacemaker implantation, the steepest part of the learning curve appears to be over the first 30‐50 cases. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 10(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 10(2019)
- Issue Display:
- Volume 30, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 10
- Issue Sort Value:
- 2019-0030-0010-0000
- Page Start:
- 1984
- Page End:
- 1993
- Publication Date:
- 2019-08-02
- Subjects:
- His bundle pacing -- His bundle pacing characteristics -- His bundle pacing feasibility -- His bundle pacing learning curve -- physiological pacing
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14064 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17276.xml