Post-heating response of concrete-filled steel tubular columns under sustained loads. (October 2019)
- Record Type:
- Journal Article
- Title:
- Post-heating response of concrete-filled steel tubular columns under sustained loads. (October 2019)
- Main Title:
- Post-heating response of concrete-filled steel tubular columns under sustained loads
- Authors:
- Ibañez, C.
Bisby, L.
Rush, D.
Romero, M.L.
Hospitaler, A. - Abstract:
- Abstract: Concrete-filled steel tubular (CFST) columns can generally be expected to better resist elevated temperatures as compared to unfilled steel hollow sections, whose evaluation after a fire is limited by the resulting deformation. A better understanding of the behaviour of CFST columns after a fire, which is dominated by the maximum temperature achieved by the concrete infill and plasticity of the steel, is required to properly estimate their residual strength and deformation and to adopt a reasonable strategy with minimum post-fire repair. In this paper, a fibre beam model for the simulation of the post-heating response of concrete-filled steel tubular (CFST) columns is presented. First, the model is validated against experimental results and subsequently it is employed to analyse the post-heating response of circular CFST columns under sustained loads. In reality, during a fire, the columns support load even during the cooling phase of a fire, so it is important to consider this loading condition when predicting the post-fire behaviour. The analysis presented in this paper comprises three stages: heating, cooling and post-fire (under sustained load) conditions. The model considers realistic features typical of the fire response of CFST columns, such as the existence of a gap conductance at the steel-concrete interface and the sliding and separation of the steel tube and the concrete. Based on the model, the response of CFST columns after heating is investigated viaAbstract: Concrete-filled steel tubular (CFST) columns can generally be expected to better resist elevated temperatures as compared to unfilled steel hollow sections, whose evaluation after a fire is limited by the resulting deformation. A better understanding of the behaviour of CFST columns after a fire, which is dominated by the maximum temperature achieved by the concrete infill and plasticity of the steel, is required to properly estimate their residual strength and deformation and to adopt a reasonable strategy with minimum post-fire repair. In this paper, a fibre beam model for the simulation of the post-heating response of concrete-filled steel tubular (CFST) columns is presented. First, the model is validated against experimental results and subsequently it is employed to analyse the post-heating response of circular CFST columns under sustained loads. In reality, during a fire, the columns support load even during the cooling phase of a fire, so it is important to consider this loading condition when predicting the post-fire behaviour. The analysis presented in this paper comprises three stages: heating, cooling and post-fire (under sustained load) conditions. The model considers realistic features typical of the fire response of CFST columns, such as the existence of a gap conductance at the steel-concrete interface and the sliding and separation of the steel tube and the concrete. Based on the model, the response of CFST columns after heating is investigated via parametric analysis. … (more)
- Is Part Of:
- Structures. Volume 21(2019)
- Journal:
- Structures
- Issue:
- Volume 21(2019)
- Issue Display:
- Volume 21, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 2019
- Issue Sort Value:
- 2019-0021-2019-0000
- Page Start:
- 90
- Page End:
- 102
- Publication Date:
- 2019-10
- Subjects:
- Post-heating response -- Residual capacity -- Fibre beam model -- Concrete-filled steel tubular columns -- Post-fire
Structural engineering -- Periodicals
624.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520124 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.istruc.2019.04.003 ↗
- Languages:
- English
- ISSNs:
- 2352-0124
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17271.xml