Benefits of an oocyte pickup simulation training program using a high-fidelity simulator (PickUpSimTM) for obstetrics and gynaecology residents: an observational survey study. (19th May 2021)
- Record Type:
- Journal Article
- Title:
- Benefits of an oocyte pickup simulation training program using a high-fidelity simulator (PickUpSimTM) for obstetrics and gynaecology residents: an observational survey study. (19th May 2021)
- Main Title:
- Benefits of an oocyte pickup simulation training program using a high-fidelity simulator (PickUpSimTM) for obstetrics and gynaecology residents: an observational survey study
- Authors:
- Corroenne, Romain
Legendre, Guillaume
Riethmuller, Didier
El-Hachem, Hady
Zhu, Katherine H.
Dreux, Cecile
Jeanneateau, Pauline
Verhaeghe, Caroline
May-Panloup, Pascale
Descamps, Philippe
Bouet, Pierre-Emmanuel - Abstract:
- Abstract: The aim of this study was to evaluate an oocyte pick-up (OPU) simulation training program for residents using the high fidelity PickUpSim TM (Accurate, Cesena, Italy) simulator. The authors carried out an observational study during an OPU simulation workshop. A successful scenario was defined as an oocyte retrieval rate ≥70% without any complications. Forty-six residents affiliated to 23 different French university hospitals were included, and 37/46 (80.4%) of them successfully completed the scenario with a mean time of 3.4 ± 1.1 minutes. The oocyte retrieval rate was 442/561 (78.8%). All residents found training beneficial and 41/46 (87%) were in favour of having simulation-based training programs for OPU in their reproductive medicine departments. All residents who had previous experience with OPU (11/11) recommended the use of a simulator before performing OPU. This study confirms that high-fidelity OPU simulation is a simple and efficient method for training residents. Impact statement: What is already known on this subject? Simulator-based training has been shown to be effective and useful for oocyte pick-up (OPU) training. What the results of this study add? All residents found the simulation program beneficial and formative, with 80% successfully completing their scenarios in a mean time of 3.4 ± 1.1 minutes. All residents who had previous experience with OPU recommended the use of a simulator before performing OPU. What the implications are of theseAbstract: The aim of this study was to evaluate an oocyte pick-up (OPU) simulation training program for residents using the high fidelity PickUpSim TM (Accurate, Cesena, Italy) simulator. The authors carried out an observational study during an OPU simulation workshop. A successful scenario was defined as an oocyte retrieval rate ≥70% without any complications. Forty-six residents affiliated to 23 different French university hospitals were included, and 37/46 (80.4%) of them successfully completed the scenario with a mean time of 3.4 ± 1.1 minutes. The oocyte retrieval rate was 442/561 (78.8%). All residents found training beneficial and 41/46 (87%) were in favour of having simulation-based training programs for OPU in their reproductive medicine departments. All residents who had previous experience with OPU (11/11) recommended the use of a simulator before performing OPU. This study confirms that high-fidelity OPU simulation is a simple and efficient method for training residents. Impact statement: What is already known on this subject? Simulator-based training has been shown to be effective and useful for oocyte pick-up (OPU) training. What the results of this study add? All residents found the simulation program beneficial and formative, with 80% successfully completing their scenarios in a mean time of 3.4 ± 1.1 minutes. All residents who had previous experience with OPU recommended the use of a simulator before performing OPU. What the implications are of these findings for clinical practice and/or further research? Prospective studies are needed to confirm the short- and long-term positive clinical impact of OPU simulation training programs. … (more)
- Is Part Of:
- Journal of obstetrics and gynaecology. Volume 41:Number 4(2021)
- Journal:
- Journal of obstetrics and gynaecology
- Issue:
- Volume 41:Number 4(2021)
- Issue Display:
- Volume 41, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2021-0041-0004-0000
- Page Start:
- 631
- Page End:
- 636
- Publication Date:
- 2021-05-19
- Subjects:
- Oocyte retrieval -- simulation -- education -- infertility -- PickUpSim
Obstetrics -- Periodicals
Gynecology -- Periodicals
618.05 - Journal URLs:
- http://informahealthcare.com/journal/jog ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/01443615.asp ↗ - DOI:
- 10.1080/01443615.2020.1789951 ↗
- Languages:
- English
- ISSNs:
- 0144-3615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5025.400000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17259.xml