3D analysis of enamel demineralisation in human dental caries using high-resolution, large field of view synchrotron X-ray micro-computed tomography. (June 2021)
- Record Type:
- Journal Article
- Title:
- 3D analysis of enamel demineralisation in human dental caries using high-resolution, large field of view synchrotron X-ray micro-computed tomography. (June 2021)
- Main Title:
- 3D analysis of enamel demineralisation in human dental caries using high-resolution, large field of view synchrotron X-ray micro-computed tomography
- Authors:
- Besnard, Cyril
Harper, Robert A.
Moxham, Thomas E.J.
James, Jonathan D.
Storm, Malte
Salvati, Enrico
Landini, Gabriel
Shelton, Richard M.
Korsunsky, Alexander M. - Abstract:
- Graphical abstract: Highlights: Unprecedented combination of resolution, field of view and contrast for the analysis human enamel carious lesions was achieved. Synchrotron X-ray micro-computed tomography revealed sub-micron details of enamel rod and inter-rod regions inaccessible by laboratory tomography. Successful segmentation and labelling allowed the extraction of enamel etching patterns and statistics. Correlation was obtained between synchrotron X-ray micro-tomography and FIB-SEM cross-section analysis. Abstract: We report major advances in the analysis of synchrotron 3D datasets acquired from human healthy and carious dental enamel. Synchrotron tomographic data for three human carious samples and a non-carious reference tooth sample were collected with the voxel size of 325 nm for a total volume of 815.4 × 815.4 × 685.4 μm 3 . The results were compared with conventional X-ray tomography, optical microscopy, and focused ion beam-scanning electron microscopy. Clear contrast was seen within demineralised enamel due to reduced mineral content using synchrotron tomography in comparison with conventional tomography. The features were found to correspond with the rod and inter-rod structures within prismatic enamel. 2D and 3D image segmentation allowed statistical quantification of important structural characteristics (such as the aspect ratio and the cross-sectional area of voids, as well as the demineralised volume fraction as a function of lesion depth). Whilst overallGraphical abstract: Highlights: Unprecedented combination of resolution, field of view and contrast for the analysis human enamel carious lesions was achieved. Synchrotron X-ray micro-computed tomography revealed sub-micron details of enamel rod and inter-rod regions inaccessible by laboratory tomography. Successful segmentation and labelling allowed the extraction of enamel etching patterns and statistics. Correlation was obtained between synchrotron X-ray micro-tomography and FIB-SEM cross-section analysis. Abstract: We report major advances in the analysis of synchrotron 3D datasets acquired from human healthy and carious dental enamel. Synchrotron tomographic data for three human carious samples and a non-carious reference tooth sample were collected with the voxel size of 325 nm for a total volume of 815.4 × 815.4 × 685.4 μm 3 . The results were compared with conventional X-ray tomography, optical microscopy, and focused ion beam-scanning electron microscopy. Clear contrast was seen within demineralised enamel due to reduced mineral content using synchrotron tomography in comparison with conventional tomography. The features were found to correspond with the rod and inter-rod structures within prismatic enamel. 2D and 3D image segmentation allowed statistical quantification of important structural characteristics (such as the aspect ratio and the cross-sectional area of voids, as well as the demineralised volume fraction as a function of lesion depth). Whilst overall carious enamel predominantly displayed a Type 1 etching pattern (preferential demineralisation of enamel rods), a transition between Type 2 (preferential inter-rod demineralisation) and Type 1 was identified within the same lesion for the first time. This study does not provide extensive results on the different lesions studied, but illustrate a new method and its potential application. … (more)
- Is Part Of:
- Materials today communications. Volume 27(2021)
- Journal:
- Materials today communications
- Issue:
- Volume 27(2021)
- Issue Display:
- Volume 27, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 2021
- Issue Sort Value:
- 2021-0027-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- Dental caries -- Enamel -- Demineralisation -- Synchrotron -- X-ray micro-computed tomography -- Optical and (focused ion beam) scanning electron microscopy
Materials science -- Periodicals
620.11 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524928 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.mtcomm.2021.102418 ↗
- Languages:
- English
- ISSNs:
- 2352-4928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17256.xml