Design of a heat recovery unit using exhaust gases for energy savings in an absorption air conditioning unit. (25th July 2021)
- Record Type:
- Journal Article
- Title:
- Design of a heat recovery unit using exhaust gases for energy savings in an absorption air conditioning unit. (25th July 2021)
- Main Title:
- Design of a heat recovery unit using exhaust gases for energy savings in an absorption air conditioning unit
- Authors:
- El-Shafie, Mostafa
Khalil Bassiouny, M.
Kambara, Shinji
El-Behery, Samy M.
Hussien, A.A. - Abstract:
- Highlights: The heat recovery unit was designed to extract heat from flue gases to preheat the Li-Br solution. The heat exchanger design specification was determined at different copper and steel tube diameters. The design analysis was theoretically executed using a FORTRAN program. The feasibility study showed that the annual fuel saving is about 23%; while the annual cost saving is 18%. The installation of the heat recovery unit will improve the absorption unit performance by 34%. Abstract: Optimum utilisation of the available energy is vital to eliminate waste heat and address other environmental issues. This study is concerned with the design of a heat exchanger for the optimum use of loss heat from flue gases. The heat content in exhaust gases can be applied in the absorption chiller to preheat a dilute solution (lithium bromide) before entering the high-temperature generator. The exploitation of the energy from a glass furnace outlet flue gas temperature of 400 °C will reduce the rate consumption of natural gas. The thermodynamic properties of flue gases were determined based on chemical composition analysis measured by the gas analyser. Moreover, the solution at the inlets and outlets of the Li-Br absorption chiller unit components was estimated using heat and mass balance equations. The heat recovery unit was designed to extract heat from flue gases to preheat, directly or indirectly, the Li-Br solution before entering the high-pressure generator using water as anHighlights: The heat recovery unit was designed to extract heat from flue gases to preheat the Li-Br solution. The heat exchanger design specification was determined at different copper and steel tube diameters. The design analysis was theoretically executed using a FORTRAN program. The feasibility study showed that the annual fuel saving is about 23%; while the annual cost saving is 18%. The installation of the heat recovery unit will improve the absorption unit performance by 34%. Abstract: Optimum utilisation of the available energy is vital to eliminate waste heat and address other environmental issues. This study is concerned with the design of a heat exchanger for the optimum use of loss heat from flue gases. The heat content in exhaust gases can be applied in the absorption chiller to preheat a dilute solution (lithium bromide) before entering the high-temperature generator. The exploitation of the energy from a glass furnace outlet flue gas temperature of 400 °C will reduce the rate consumption of natural gas. The thermodynamic properties of flue gases were determined based on chemical composition analysis measured by the gas analyser. Moreover, the solution at the inlets and outlets of the Li-Br absorption chiller unit components was estimated using heat and mass balance equations. The heat recovery unit was designed to extract heat from flue gases to preheat, directly or indirectly, the Li-Br solution before entering the high-pressure generator using water as an intermediate solution. The heat exchanger design specification was determined for both cold fluids (Li-Br and H2 O) at different tube diameters using copper and steel materials. Furthermore, the theoretical design analysis was executed using a FORTRAN program. It was found that the compact direct heat exchanger showed the best performance with respect to the overall heat transfer area, while the shell-and-tube heat exchanger was favourable because of its simple design and manufacturing. The results showed that the minimum outlet flue gas temperature was 200 °C to keep the glass furnace operating as a natural draught system. The feasibility study was carried out by the CONSUKORRA Company (Hitachi agent in Egypt) based on the current study data. The proposed feasibility study showed that the annual fuel savings was about 23%, while the annual cost saving was 18%. Moreover, the coefficient of performance of absorption unit will be enhanced by 34% after installing the heat recovery unit. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 194(2021)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 194(2021)
- Issue Display:
- Volume 194, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 194
- Issue:
- 2021
- Issue Sort Value:
- 2021-0194-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07-25
- Subjects:
- Glass furnace -- Energy saving -- Heat exchanger -- Heat recovery -- Feasibility study
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2021.117031 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17256.xml