Dosimetric impacts of beam-hardening filter removal for the CyberKnife system. (June 2021)
- Record Type:
- Journal Article
- Title:
- Dosimetric impacts of beam-hardening filter removal for the CyberKnife system. (June 2021)
- Main Title:
- Dosimetric impacts of beam-hardening filter removal for the CyberKnife system
- Authors:
- Kamomae, Takeshi
Matsunaga, Takuma
Suzuki, Junji
Okudaira, Kuniyasu
Kawabata, Fumitaka
Kato, Yutaka
Oguchi, Hiroshi
Shimizu, Morihito
Sasaki, Motoharu
Takase, Yuki
Kawamura, Mariko
Ohtakara, Kazuhiro
Itoh, Yoshiyuki
Naganawa, Shinji - Abstract:
- Highlights: Beam quality correction factors for CyberKnife after beam-hardening filter removal. Photon energy fluence spectrum was softened by the removal of beam-hardening filter. No remarkable impact was observed for the beam quality correction factors. Abstract: Purpose: Equipment refurbishment was performed to remove the beam-hardening filter (BHF) from the CyberKnife system (CK). This study aimed to confirm the change in the beam characteristics between the conventional CK (present-BHF CK) and CK after the BHF was removed (absent-BHF CK) and evaluate the impact of BHF removal on the beam quality correction factors k Q . Methods: The experimental measurements of the beam characteristics of the present- and absent-BHF CKs were compared. The CKs were modeled using Monte Carlo simulations (MCs). The energy fluence spectra were calculated using MCs. Finally, k Q were estimated by combining the MC results and analytic calculations based on the TRS-398 and TRS-483 approaches. Results: All gamma values for percent depth doses and beam profiles between each CK were less than 0.5 following the 3%/1 mm criteria. The percentage differences for tissue-phantom ratios at depths of 20 and 10 cm and percentage depth doses at 10 cm between each CK were −1.20% and −0.97%, respectively. The MC results demonstrated that the photon energy fluence spectrum of the absent-BHF CK was softer than that of the present-BHF CK. The k Q values for the absent-BHF CK were in agreement within 0.02% withHighlights: Beam quality correction factors for CyberKnife after beam-hardening filter removal. Photon energy fluence spectrum was softened by the removal of beam-hardening filter. No remarkable impact was observed for the beam quality correction factors. Abstract: Purpose: Equipment refurbishment was performed to remove the beam-hardening filter (BHF) from the CyberKnife system (CK). This study aimed to confirm the change in the beam characteristics between the conventional CK (present-BHF CK) and CK after the BHF was removed (absent-BHF CK) and evaluate the impact of BHF removal on the beam quality correction factors k Q . Methods: The experimental measurements of the beam characteristics of the present- and absent-BHF CKs were compared. The CKs were modeled using Monte Carlo simulations (MCs). The energy fluence spectra were calculated using MCs. Finally, k Q were estimated by combining the MC results and analytic calculations based on the TRS-398 and TRS-483 approaches. Results: All gamma values for percent depth doses and beam profiles between each CK were less than 0.5 following the 3%/1 mm criteria. The percentage differences for tissue-phantom ratios at depths of 20 and 10 cm and percentage depth doses at 10 cm between each CK were −1.20% and −0.97%, respectively. The MC results demonstrated that the photon energy fluence spectrum of the absent-BHF CK was softer than that of the present-BHF CK. The k Q values for the absent-BHF CK were in agreement within 0.02% with those for the present-BHF CK. Conclusions: The photon energy fluence spectrum was softened by the removal of BHF. However, no remarkable impact was observed for the measured beam characteristics and k Q . Therefore, the previous findings of the k Q values for the present-BHF CK can be directly used for the absent-BHF CK. … (more)
- Is Part Of:
- Physica medica. Volume 86(2021)
- Journal:
- Physica medica
- Issue:
- Volume 86(2021)
- Issue Display:
- Volume 86, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 2021
- Issue Sort Value:
- 2021-0086-2021-0000
- Page Start:
- 98
- Page End:
- 105
- Publication Date:
- 2021-06
- Subjects:
- CyberKnife -- Beam quality correction factor -- Beam-hardening filter -- Monte Carlo simulation
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.05.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17259.xml