Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis. (April 2021)
- Record Type:
- Journal Article
- Title:
- Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis. (April 2021)
- Main Title:
- Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis
- Authors:
- Edmund, Jens M.
Andreasen, Daniel
Van Leemput, Koen - Abstract:
- Highlights: MRI-only IGRT accuracy is ≤2 mm as compared to CT but significant differences were observed. MRI-only CBCT-based IGRT seems feasible but caution is advised. The median absolute error (MeAE) for independent verification on the sCT quality is proposed. A MeAE around 0.1 in mass density could call for sCT quality inspection. Abstract: Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carriedHighlights: MRI-only IGRT accuracy is ≤2 mm as compared to CT but significant differences were observed. MRI-only CBCT-based IGRT seems feasible but caution is advised. The median absolute error (MeAE) for independent verification on the sCT quality is proposed. A MeAE around 0.1 in mass density could call for sCT quality inspection. Abstract: Background and purpose: Radiotherapy (RT) based on magentic resonance imaging (MRI) only is currently used clinically in the pelvis. A synthetic computed tomography (sCT) is needed for dose planning. Here, we investigate the accuracy of cone beam CT (CBCT) based MRI-only image guided RT (IGRT) and sCT image quality. Materials and methods: CT, MRI and CBCT scans of ten prostate cancer patients were included. The MRI was converted to a sCT using a multi-atlas approach. The sCT, CT and MR images were auto-matched with the CBCT on the bony anatomy. Paired sCT-CT and sCT-CBCT data were created. CT numbers were converted to relative electron (RED) and mass densities (DES) using a standard calibration curve for the CT and sCT. For the CBCT RED/DES conversion, a phantom and paired CT-CBCT population based calibration curve was used. For the latter, the CBCT numbers were averaged in 100 HU bins and the known RED/DES of the CT were assigned. The paired sCT-CT and sCT-CBCT data were averaged in bins of 10 HU or 0.01 RED/DES. The median absolute error (MeAE) between the sCT-CT and sCT-CBCT bins was calculated. Wilcoxon rank-sum tests were carried out for the IGRT and MeAE study. Results: The mean sCT or MR IGRT difference from CT was ≤ 2 mm but significant differences were observed. A CBCT HU or phantom-based RED/DES MeAE did not estimate the sCT quality similar to a CT based MeAE but the CBCT population-based RED/DES MeAE did. Conclusions: MRI-only CBCT-based IGRT seems feasible but caution is advised. A MeAE around 0.1 DES could call for sCT quality inspection. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 18(2021)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 18(2021)
- Issue Display:
- Volume 18, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 18
- Issue:
- 2021
- Issue Sort Value:
- 2021-0018-2021-0000
- Page Start:
- 55
- Page End:
- 60
- Publication Date:
- 2021-04
- Subjects:
- MRI-only RT -- IGRT -- Synthetic CT -- Pseudo CT -- Magnetic resonance imaging -- Radiotherapy -- Cone beam CT
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2021.05.001 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17249.xml