Flow regime identification of steam-water two-phase flow using optical probes, based on local parameters in vertical tube bundles. (June 2021)
- Record Type:
- Journal Article
- Title:
- Flow regime identification of steam-water two-phase flow using optical probes, based on local parameters in vertical tube bundles. (June 2021)
- Main Title:
- Flow regime identification of steam-water two-phase flow using optical probes, based on local parameters in vertical tube bundles
- Authors:
- Wang, Teng
Liu, Zhaohui
Gui, Miao
Bi, Qincheng
Sui, Zhiqiang - Abstract:
- Abstract: Flow regime identification based on local parameters of axial upward two-phase flow in vertical tube bundles, at high-temperature and high-pressure, was performed using optical probes. A staggered arrangement of the tube bundles was simulated inside a non-circular test channel, the tube size and pitch are same as that in a real steam generator of a PWR under design. Optical probes were utilized to acquire the void fraction, interface frequency, and fluctuation characteristics of the local void fraction at two typical locations (centroid of the three tubes, named op-1, and centre of the minimum gap between two tubes, named op-2). The system pressure ranged from 5 to 9 MPa, mass flux from 100 to 350 kg m −2 s −1, thermodynamic steam quality from 0 to 1, and inlet fluid temperature from 263.9 to 303.3 °C, depending on the saturation pressure. This study investigated local parameters and flow pattern characteristics of high-pressure steam-water two-phase flow in vertical tube bundles using optical probes, with the measurement error of less than 2%. Results showed that local void fraction at op-1 was much larger than that at op-2, and the local void fraction difference between op-1 and op-2 increased first and then gradually decreased, which was primarily affected by the transition in flow regimes. The flow pattern characteristics of steam-water two-phase flow were described based on three aspects, namely, variation in interface frequency with local void fraction,Abstract: Flow regime identification based on local parameters of axial upward two-phase flow in vertical tube bundles, at high-temperature and high-pressure, was performed using optical probes. A staggered arrangement of the tube bundles was simulated inside a non-circular test channel, the tube size and pitch are same as that in a real steam generator of a PWR under design. Optical probes were utilized to acquire the void fraction, interface frequency, and fluctuation characteristics of the local void fraction at two typical locations (centroid of the three tubes, named op-1, and centre of the minimum gap between two tubes, named op-2). The system pressure ranged from 5 to 9 MPa, mass flux from 100 to 350 kg m −2 s −1, thermodynamic steam quality from 0 to 1, and inlet fluid temperature from 263.9 to 303.3 °C, depending on the saturation pressure. This study investigated local parameters and flow pattern characteristics of high-pressure steam-water two-phase flow in vertical tube bundles using optical probes, with the measurement error of less than 2%. Results showed that local void fraction at op-1 was much larger than that at op-2, and the local void fraction difference between op-1 and op-2 increased first and then gradually decreased, which was primarily affected by the transition in flow regimes. The flow pattern characteristics of steam-water two-phase flow were described based on three aspects, namely, variation in interface frequency with local void fraction, fluctuation characteristics of local void fraction, and statistical analysis of local void fraction deviating from the average. Additionally, the flow regime identification criteria, applicable to the steam-water two-phase flow in vertical tube bundles, were proposed based on local parameters. Highlights: A new tube bundle geometry was designed and applied to this study. Optical probes were utilized to acquire the extensive local parameters. Effects of flow patterns on local parameters were discussed. Flow regime identification criteria were proposed. … (more)
- Is Part Of:
- Flow measurement and instrumentation. Volume 79(2021)
- Journal:
- Flow measurement and instrumentation
- Issue:
- Volume 79(2021)
- Issue Display:
- Volume 79, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 79
- Issue:
- 2021
- Issue Sort Value:
- 2021-0079-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- Steam generator -- Tube bundles -- Void fraction -- Flow regime identification -- Optical probe
Fluid dynamic measurements -- Periodicals
Flow meters -- Periodicals
Fluides, Dynamique des -- Mesure -- Périodiques
Débitmètres -- Périodiques
681.2805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09555986 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.flowmeasinst.2021.101928 ↗
- Languages:
- English
- ISSNs:
- 0955-5986