Quadrupole detection FT‐ICR mass spectrometry offers deep profiling of residue oil: A systematic comparison of 2ω 7 Tesla versus 15 Tesla instruments. Issue 5 (24th November 2020)
- Record Type:
- Journal Article
- Title:
- Quadrupole detection FT‐ICR mass spectrometry offers deep profiling of residue oil: A systematic comparison of 2ω 7 Tesla versus 15 Tesla instruments. Issue 5 (24th November 2020)
- Main Title:
- Quadrupole detection FT‐ICR mass spectrometry offers deep profiling of residue oil: A systematic comparison of 2ω 7 Tesla versus 15 Tesla instruments
- Authors:
- Ge, Jinfeng
Ma, Chao
Qi, Yulin
Wang, Xiaowei
Wang, Wei
Hu, Miao
Hu, Qiaozhuan
Yi, Yuan‐Bi
Shi, Dejun
Yue, Fu‐Jun
Li, Si‐Liang
Volmer, Dietrich A. - Abstract:
- Abstract: Mass resolving power is one of the key features of Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS), which enables the molecular characterization of complex mixtures. Quadrupole (2ω) detection provides a significant step forward in FT‐ICR MS performance, as it doubles the resolving power for a given signal acquisition time. Whether this 2ω detection technique truly substitutes for a higher magnetic field remains unknown however. In this study, a residue oil sample was characterized using both a 2ω 7 Tesla FT‐ICR and a 15 Tesla FT‐ICR instrument, and analytical figures of merit were systematically compared. It was shown that 2ω 7T FT‐ICR MS provided comparable performance in the deep profiling of the complex oil sample, with better signal intensities and reproducibilities for absorption‐mode processing. The 15T FT‐ICR MS gave more precise measurements with better estimates of the sample's elemental compositions. To the best of our knowledge, this is the first published study, which thoroughly compared the performance of 2ω detection on a low magnetic field instrument with that of a high magnetic field FT‐ICR‐MS.
- Is Part Of:
- Analytical Science Advances. Volume 2:Issue 5/6(2021)
- Journal:
- Analytical Science Advances
- Issue:
- Volume 2:Issue 5/6(2021)
- Issue Display:
- Volume 2, Issue 5/6 (2021)
- Year:
- 2021
- Volume:
- 2
- Issue:
- 5/6
- Issue Sort Value:
- 2021-0002-NaN-0000
- Page Start:
- 272
- Page End:
- 278
- Publication Date:
- 2020-11-24
- Subjects:
- FT‐ICR MS -- quadrupole detection -- residue oil -- resolving power
Chemistry, Analytic -- Periodicals
Science -- Periodicals
543 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
https://onlinelibrary.wiley.com/loi/26285452 ↗ - DOI:
- 10.1002/ansa.202000123 ↗
- Languages:
- English
- ISSNs:
- 2628-5452
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17237.xml