Change in the local impedance and electrograms recorded by a micro‐electrode tip catheter during initial atrial fibrillation ablation. Issue 3 (7th April 2021)
- Record Type:
- Journal Article
- Title:
- Change in the local impedance and electrograms recorded by a micro‐electrode tip catheter during initial atrial fibrillation ablation. Issue 3 (7th April 2021)
- Main Title:
- Change in the local impedance and electrograms recorded by a micro‐electrode tip catheter during initial atrial fibrillation ablation
- Authors:
- Hashimoto, Kenji
Tsuzuki, Ippei
Seki, Yuta
Ibe, Susumu
Yamashita, Terumasa
Miyama, Hiroshi
Fujisawa, Taishi
Katsumata, Yoshinori
Kimura, Takehiro
Fukuda, Keiichi
Takatsuki, Seiji - Abstract:
- Abstract: Background: A novel measurement of the local impedance (LI) and electrograms recorded from micro‐electrodes on catheter tip has been developed. However, the data during pulmonary vein (PV) ablation is not sufficient. We aimed to investigate the utility of this measurement during initial atrial fibrillation (AF) ablation. Methods: We investigated 111 representative radiofrequency applications in 7 AF patients without a history of prior ablation (6 males, age 68 [65‐72] years, 2 persistent AF). The ablation strategy was PV isolation for paroxysmal AF and single ring box isolation for persistent AF, using MiFi catheter. The correlation of the generator impedance (GI) drop and LI drop after radiofrequency applications and the predictive value of the initial LI elevation before radiofrequency applications for LI drop were analyzed. Also, the LI and GI drop were investigated according to the location of RF applications. Results: The LI drop was higher than GI drop (23.7 [16.4‐35.7] and 9.0 [6.0‐12.0]; P < .01). There were correlations between the initial LI elevation and LI drop ( R 2 = 0.466, P < .01) and between the LI and GI drop ( R 2 = 0.263, P < .01). The LI drops significantly differed according to the different anatomical localizations by the Kruskal–Wallis test, although the GI drops did not differ ( P < .01 and P = .49, respectively) Conclusion: LI drop was associated with initial LI elevation and was larger than GI drop. LI drop was different accordingAbstract: Background: A novel measurement of the local impedance (LI) and electrograms recorded from micro‐electrodes on catheter tip has been developed. However, the data during pulmonary vein (PV) ablation is not sufficient. We aimed to investigate the utility of this measurement during initial atrial fibrillation (AF) ablation. Methods: We investigated 111 representative radiofrequency applications in 7 AF patients without a history of prior ablation (6 males, age 68 [65‐72] years, 2 persistent AF). The ablation strategy was PV isolation for paroxysmal AF and single ring box isolation for persistent AF, using MiFi catheter. The correlation of the generator impedance (GI) drop and LI drop after radiofrequency applications and the predictive value of the initial LI elevation before radiofrequency applications for LI drop were analyzed. Also, the LI and GI drop were investigated according to the location of RF applications. Results: The LI drop was higher than GI drop (23.7 [16.4‐35.7] and 9.0 [6.0‐12.0]; P < .01). There were correlations between the initial LI elevation and LI drop ( R 2 = 0.466, P < .01) and between the LI and GI drop ( R 2 = 0.263, P < .01). The LI drops significantly differed according to the different anatomical localizations by the Kruskal–Wallis test, although the GI drops did not differ ( P < .01 and P = .49, respectively) Conclusion: LI drop was associated with initial LI elevation and was larger than GI drop. LI drop was different according to locations, although GI drop was not. These findings might indicate that LI drop would be a more sensitive marker for lesion formation than GI drop. Abstract : Utility of the novel measurement of the local impedance during initial atrial fibrillation ablation was investigated. The local impedance drop during radiofrequency applications was higher than the generator impedance drop, both of which were positively correlated. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 37:Issue 3(2021)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 37:Issue 3(2021)
- Issue Display:
- Volume 37, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 37
- Issue:
- 3
- Issue Sort Value:
- 2021-0037-0003-0000
- Page Start:
- 566
- Page End:
- 573
- Publication Date:
- 2021-04-07
- Subjects:
- atrial fibrillation -- catheter ablation -- impedance
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12535 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18447.xml