An in vitro study of pressure increases during contrast injections in diagnostic cerebral angiography. Issue 5 (October 2021)
- Record Type:
- Journal Article
- Title:
- An in vitro study of pressure increases during contrast injections in diagnostic cerebral angiography. Issue 5 (October 2021)
- Main Title:
- An in vitro study of pressure increases during contrast injections in diagnostic cerebral angiography
- Authors:
- Marfoglio, Samantha
Kovarovic, Brandon
Hou, Wei
Fiorella, David J
Sadasivan, Chander - Abstract:
- Background: During diagnostic cerebral angiography, the contrast bolus injected into a vessel can cause substantial changes in baseline pressures and flows. One potential, and serious complication is the re-rupture of aneurysms due to these injections. The goals of this in vitro study were to evaluate the effect of injection conditions on intraneurysmal pressure changes during angiography. Methods: A silicone replica of a complete circle of Willis model with ophthalmic, anterior communicating, and basilar tip aneurysms was connected to a physiologically accurate flow pump. Contrast injections were performed under different conditions (carotid or vertebral vessel imaging, catheter diameter, injection rate, injection time, and arterial blood flow rate) and the pressure in each aneurysm was recorded before and during each injection. The effect of injection conditions on percentage increase in aneurysm pressures was statistically assessed. Additionally, the effect of the distance between the aneurysm and the catheter-tip on aneurysmal pressures was assessed. Results: Mean intraneurysmal pressures during injection (84.5 ± 10.8 mmHg) were significantly higher than pre-injection pressures (80.4 ± 10.6 mmHg, p < 0.0001). Only 3 of the 5 conditions – carotid injections, higher injection rates, and smaller catheter diameters – significantly increased intraneurysmal pressures. The catheter-tip distance showed no correlation to pressure increases. Conclusions: Increasing contrastBackground: During diagnostic cerebral angiography, the contrast bolus injected into a vessel can cause substantial changes in baseline pressures and flows. One potential, and serious complication is the re-rupture of aneurysms due to these injections. The goals of this in vitro study were to evaluate the effect of injection conditions on intraneurysmal pressure changes during angiography. Methods: A silicone replica of a complete circle of Willis model with ophthalmic, anterior communicating, and basilar tip aneurysms was connected to a physiologically accurate flow pump. Contrast injections were performed under different conditions (carotid or vertebral vessel imaging, catheter diameter, injection rate, injection time, and arterial blood flow rate) and the pressure in each aneurysm was recorded before and during each injection. The effect of injection conditions on percentage increase in aneurysm pressures was statistically assessed. Additionally, the effect of the distance between the aneurysm and the catheter-tip on aneurysmal pressures was assessed. Results: Mean intraneurysmal pressures during injection (84.5 ± 10.8 mmHg) were significantly higher than pre-injection pressures (80.4 ± 10.6 mmHg, p < 0.0001). Only 3 of the 5 conditions – carotid injections, higher injection rates, and smaller catheter diameters – significantly increased intraneurysmal pressures. The catheter-tip distance showed no correlation to pressure increases. Conclusions: Increasing contrast injection rates and decreasing catheter diameters are correlated to intraneurysmal pressure increases during angiography irrespective of the distance to the catheter tip. Future in vivo studies are required to confirm these findings and determine whether the amplitude of pressure increases with commonly used injection rates can be clinically detrimental. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 27:Issue 5(2021)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 27:Issue 5(2021)
- Issue Display:
- Volume 27, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2021-0027-0005-0000
- Page Start:
- 695
- Page End:
- 702
- Publication Date:
- 2021-10
- Subjects:
- Injection rate -- catheter diameter -- catheter distance -- injection volume -- blood flow rate
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019921996099 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17602.xml