Shear resistance of cold-formed thin-walled steel inter-story connections. (August 2021)
- Record Type:
- Journal Article
- Title:
- Shear resistance of cold-formed thin-walled steel inter-story connections. (August 2021)
- Main Title:
- Shear resistance of cold-formed thin-walled steel inter-story connections
- Authors:
- Zou, Yuxuan
Zhou, Xuhong
Shi, Yu
Wang, Zhijun
Ke, Ke
Zhang, Zepeng
Guan, Yu - Abstract:
- Abstract: A composite wall is the primary lateral force-resisting system in a cold-formed thin-walled steel structural system. The shear force between the upper and lower walls is transmitted through an inter-story connection in the cold-formed thin-walled steel platform framing system. In this study, the 16 platform framing inter-story connection specimens were subjected to cyclic loading to study the shear resistance, the failure modes, deformation, and the influence of stiffeners, lateral rigid blocking, X-shaped straps, and vertical. Hysteretic curves, skeleton curves, shear bearing capacity, and lateral stiffness values were obtained from the testing. The results showed that the specimens with only stiffeners had a lower shear capacity and lateral stiffness, which were significantly affected by the vertical force. Further, short stiffeners were not fully effective. The highest shear capacity and lateral stiffness values were characterized for the specimens with rigid blocking. Increasing the rigid blocking improved the shear resistance of the specimens, and rigid blocking with the same height as the floor joists contributed to excellent shear capacity and lateral stiffness of the specimens under vertical loading. The lateral stiffness of the inter-story connection was also significantly increased by using X-shaped straps, and the vertical force resulted in substantial decrease of the lateral stiffness. Based on the test results and a comparison of the nominal shearAbstract: A composite wall is the primary lateral force-resisting system in a cold-formed thin-walled steel structural system. The shear force between the upper and lower walls is transmitted through an inter-story connection in the cold-formed thin-walled steel platform framing system. In this study, the 16 platform framing inter-story connection specimens were subjected to cyclic loading to study the shear resistance, the failure modes, deformation, and the influence of stiffeners, lateral rigid blocking, X-shaped straps, and vertical. Hysteretic curves, skeleton curves, shear bearing capacity, and lateral stiffness values were obtained from the testing. The results showed that the specimens with only stiffeners had a lower shear capacity and lateral stiffness, which were significantly affected by the vertical force. Further, short stiffeners were not fully effective. The highest shear capacity and lateral stiffness values were characterized for the specimens with rigid blocking. Increasing the rigid blocking improved the shear resistance of the specimens, and rigid blocking with the same height as the floor joists contributed to excellent shear capacity and lateral stiffness of the specimens under vertical loading. The lateral stiffness of the inter-story connection was also significantly increased by using X-shaped straps, and the vertical force resulted in substantial decrease of the lateral stiffness. Based on the test results and a comparison of the nominal shear strength values required by current specifications, this study proposed improvements to the design of cold-formed thin-walled steel platform framing inter-story connections. Graphical abstarct: Unlabelled Image Highlights: Low cyclic loading tests were performed on 16 inter-story connection specimens. Hysteretic curves, skeleton curves, shear bearing capacity, and lateral stiffness values were obtained. It deals with the impacts of stiffeners, lateral rigid blocking, X-shaped straps, vertical forces, amount and height. It provides improvements to the design of cold-formed thin-walled steel inter-story connections. … (more)
- Is Part Of:
- Journal of constructional steel research. Volume 183(2021)
- Journal:
- Journal of constructional steel research
- Issue:
- Volume 183(2021)
- Issue Display:
- Volume 183, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 183
- Issue:
- 2021
- Issue Sort Value:
- 2021-0183-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Cold-formed steel -- Inter-story connection -- Lateral capacity -- Experimental investigation
Steel, Structural -- Periodicals
Building, Iron and steel -- Periodicals
Acier de construction -- Périodiques
Construction métallique -- Périodiques
624.1821 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0143974X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcsr.2021.106757 ↗
- Languages:
- English
- ISSNs:
- 0143-974X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.193000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17228.xml