A modified method of on-line solid phase extraction and fluorometric detection for underway monitoring and onboard analysis of trace ammonium in seawater. (July 2021)
- Record Type:
- Journal Article
- Title:
- A modified method of on-line solid phase extraction and fluorometric detection for underway monitoring and onboard analysis of trace ammonium in seawater. (July 2021)
- Main Title:
- A modified method of on-line solid phase extraction and fluorometric detection for underway monitoring and onboard analysis of trace ammonium in seawater
- Authors:
- Wang, Ting
Huang, Yongming
Xu, Jin
Guo, Weidong
Zhu, Yong
Yuan, Dongxing - Abstract:
- Abstract: A sensitive and automated method for underway and onboard analysis of trace ammonium in seawater was established using on-line solid phase extraction and fluorescence detection. Ammonium reacted with o -phthalaldehyde and sulfite to produce isoindole derivative that was concentrated on a hydrophilic lipophilic balanced (HLB) cartridge and then rapidly eluted with ethanol and measured using a fluorescence detector. The work was modified from our previous developed method, where 30 mL of a seawater sample was introduced into a reaction bottle with a 10 mL pipette. In the modified method a 10 mL sample loop was adopted for sample introduction to reduce possible contamination caused by manual operation. More importantly, the present method makes underway monitoring much more automatic. The detection limit was 3.5 nmol L −1, and the relative standard deviation was 3.52% (n = 12) for a sample spiked with 40 nmol L −1 ammonium standard. The method was free of the effects of salinity, carry-over and dissolved organic matter, with recoveries between 94.0% and 106.1%. An equation was introduced to correct matrix effects, and pure water and seawater blank were found to be equivalent to ammonium concentration of 8.1 ± 2.2 nmol L −1 and 6.0 ± 0.8 nmol L −1, respectively. The correction method can also be introduced to determination of other trace analytes where matrix effect cannot be neglected. A technique of stopped-flow was adopted and stopped-flow time could be adjustedAbstract: A sensitive and automated method for underway and onboard analysis of trace ammonium in seawater was established using on-line solid phase extraction and fluorescence detection. Ammonium reacted with o -phthalaldehyde and sulfite to produce isoindole derivative that was concentrated on a hydrophilic lipophilic balanced (HLB) cartridge and then rapidly eluted with ethanol and measured using a fluorescence detector. The work was modified from our previous developed method, where 30 mL of a seawater sample was introduced into a reaction bottle with a 10 mL pipette. In the modified method a 10 mL sample loop was adopted for sample introduction to reduce possible contamination caused by manual operation. More importantly, the present method makes underway monitoring much more automatic. The detection limit was 3.5 nmol L −1, and the relative standard deviation was 3.52% (n = 12) for a sample spiked with 40 nmol L −1 ammonium standard. The method was free of the effects of salinity, carry-over and dissolved organic matter, with recoveries between 94.0% and 106.1%. An equation was introduced to correct matrix effects, and pure water and seawater blank were found to be equivalent to ammonium concentration of 8.1 ± 2.2 nmol L −1 and 6.0 ± 0.8 nmol L −1, respectively. The correction method can also be introduced to determination of other trace analytes where matrix effect cannot be neglected. A technique of stopped-flow was adopted and stopped-flow time could be adjusted depending on the concentration of ammonium in the seawater samples. The sample throughput was 7–9 h −1, and the method permitted the analysis of samples over a wide range of concentrations. The modified method has been successfully applied for shipboard underway determination of ammonium in a coastal area and shipboard determination the ammonium concentration of discrete samples in three vertical profiles during a cruise in the South China Sea. Highlights: An on-line automated shipboard underway analyzer was developed for continuously monitoring ammonium in seawater. The modifications included establishing an automated sample loading way, improving the elution mode, optimizing reagent dosage. Field tests were successfully carried out to prove the practicability. … (more)
- Is Part Of:
- Deep sea research. Volume 173(2021)
- Journal:
- Deep sea research
- Issue:
- Volume 173(2021)
- Issue Display:
- Volume 173, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 173
- Issue:
- 2021
- Issue Sort Value:
- 2021-0173-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Ammonium -- Flow analysis -- Fluorescence detection -- Seawater -- Matrix blank -- Underway determination
Oceanography -- Periodicals
Océanographie -- Périodiques
551.4605 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09670637 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.dsr.2021.103547 ↗
- Languages:
- English
- ISSNs:
- 0967-0637
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3540.955500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17222.xml