Echocardiographic assessment of chamber size and ventricular function during the first year after heart transplantation. (7th May 2021)
- Record Type:
- Journal Article
- Title:
- Echocardiographic assessment of chamber size and ventricular function during the first year after heart transplantation. (7th May 2021)
- Main Title:
- Echocardiographic assessment of chamber size and ventricular function during the first year after heart transplantation
- Authors:
- Ingvarsson, Annika
Werther Evaldsson, Anna
Waktare, Johan
Braun, Oscar
Smith, Gustav Jan
Roijer, Anders
Rådegran, Göran
Meurling, Carl - Abstract:
- Abstract: Aims: Detecting changes in ventricular function after orthotopic heart transplantation (OHT) using transthoracic echocardiography (TTE) is important but interpretation of findings is complicated by lack of data on early graft adaptation. We sought to evaluate echocardiographic measures of ventricular size and function the first year following OHT including speckle tracking derived strain. We also aimed to compare echocardiographic findings to haemodynamic parameters obtained by right heart catheterization (RHC). Methods and results: Fifty OHT patients were examined prospectively with TTE and RHC at 1, 6, and 12 months after OHT. Left ventricle (LV) was assessed with fractional shortening, ejection fraction and systolic tissue velocities. Right ventricular (RV) evaluation included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S´) and fractional area change (FAC). LV global longitudinal and circumferential strain and RV global longitudinal strain (GLS) and RV lateral wall strain (RVfree) were analysed. No relevant changes occurred in LV echocardiographic parameters, whereas all measures of RV function improved significantly during follow‐up. There was an increase in TAPSE (12.4 ± 3.3 mm to 14.4 ± 4.3 mm, p < .01), FAC (36% ± 8% to 41% ± 8%, p < .01), RV GLS (−15.8% ± 4% to −17.8% ± 3.6%, p < .01), and RVfree (−15.5% ± 3.7% to −18.6% ± 3.6%, p < .001). Between 1 and 12 months, pulmonary pressures decreased, whereas pulmonaryAbstract: Aims: Detecting changes in ventricular function after orthotopic heart transplantation (OHT) using transthoracic echocardiography (TTE) is important but interpretation of findings is complicated by lack of data on early graft adaptation. We sought to evaluate echocardiographic measures of ventricular size and function the first year following OHT including speckle tracking derived strain. We also aimed to compare echocardiographic findings to haemodynamic parameters obtained by right heart catheterization (RHC). Methods and results: Fifty OHT patients were examined prospectively with TTE and RHC at 1, 6, and 12 months after OHT. Left ventricle (LV) was assessed with fractional shortening, ejection fraction and systolic tissue velocities. Right ventricular (RV) evaluation included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S´) and fractional area change (FAC). LV global longitudinal and circumferential strain and RV global longitudinal strain (GLS) and RV lateral wall strain (RVfree) were analysed. No relevant changes occurred in LV echocardiographic parameters, whereas all measures of RV function improved significantly during follow‐up. There was an increase in TAPSE (12.4 ± 3.3 mm to 14.4 ± 4.3 mm, p < .01), FAC (36% ± 8% to 41% ± 8%, p < .01), RV GLS (−15.8% ± 4% to −17.8% ± 3.6%, p < .01), and RVfree (−15.5% ± 3.7% to −18.6% ± 3.6%, p < .001). Between 1 and 12 months, pulmonary pressures decreased, whereas pulmonary vascular resistance did not. Conclusion: Stable OHT recipients reached steady state regarding LV function 1 month after transplantation. In contrast, RV function displayed gradual improvement the first year following OHT, indicating delayed RV adaptation as compared to the LV. Improved RV function parameters were independent of invasively measured pulmonary pressures. … (more)
- Is Part Of:
- Clinical physiology and functional imaging. Volume 41:Number 4(2021)
- Journal:
- Clinical physiology and functional imaging
- Issue:
- Volume 41:Number 4(2021)
- Issue Display:
- Volume 41, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2021-0041-0004-0000
- Page Start:
- 355
- Page End:
- 365
- Publication Date:
- 2021-05-07
- Subjects:
- 2‐dimensional echocardiography -- cardiac allograft -- early follow‐up -- right heart catheterisation -- speckle tracking -- strain
Physiology, Pathological -- Periodicals
Diagnostic imaging -- Periodicals
612 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=cpf ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cpf.12702 ↗
- Languages:
- English
- ISSNs:
- 1475-0961
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.333520
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17218.xml