Effect of opaque wraps for pulse oximeter sensors: randomised cross-over trial. Issue 1 (1st July 2020)
- Record Type:
- Journal Article
- Title:
- Effect of opaque wraps for pulse oximeter sensors: randomised cross-over trial. Issue 1 (1st July 2020)
- Main Title:
- Effect of opaque wraps for pulse oximeter sensors: randomised cross-over trial
- Authors:
- Kannan Loganathan, Prakash
O'Shea, Joyce E
Harikumar, Chidambara
Brigham, John C
Rabi, Yacov
Gupta, Samir - Abstract:
- Abstract : Background: Evidence is lacking as to whether ambient light or phototherapy light could interfere with pulse oximeter performance. Methods: In this randomised cross-over trial, we recruited neonates of gestation >24 weeks. Consented infants were randomly assigned to either pulse oximeter sensor with opaque wrap or without opaque wrap. Nellcor and Masimo sensors were applied simultaneously to different feet for 10 min of recording. Infants were crossed over to the other intervention for a further 10 min, totalling 20 min recording per infant. Primary outcome was faster acquisition of data with shielding of pulse oximeter sensor as compared with not shielding. Results: A total of 96 babies were recruited. There was no difference in primary outcome of time taken to display valid data between the two groups (opaque wrap: 12.73±3.1 s vs no opaque wrap: 13.16±3.3 s, p=0.27). There was no difference in any of the secondary outcomes (percentage of valid data points, percentage of time saturation below target, and so on) between the two groups in both pulse oximeters. Masimo sensor readings displayed a higher mean oxygen saturation (mean difference of 2.85, p=0.001) and lower percentage of time saturation below 94% (mean difference of −27.8, p=0.001) than Nellcor in both groups. There was no difference in any of the outcomes in babies receiving phototherapy (n=21). Conclusion: In this study, shielding the pulse oximeter sensor from ambient light or phototherapy light didAbstract : Background: Evidence is lacking as to whether ambient light or phototherapy light could interfere with pulse oximeter performance. Methods: In this randomised cross-over trial, we recruited neonates of gestation >24 weeks. Consented infants were randomly assigned to either pulse oximeter sensor with opaque wrap or without opaque wrap. Nellcor and Masimo sensors were applied simultaneously to different feet for 10 min of recording. Infants were crossed over to the other intervention for a further 10 min, totalling 20 min recording per infant. Primary outcome was faster acquisition of data with shielding of pulse oximeter sensor as compared with not shielding. Results: A total of 96 babies were recruited. There was no difference in primary outcome of time taken to display valid data between the two groups (opaque wrap: 12.73±3.1 s vs no opaque wrap: 13.16±3.3 s, p=0.27). There was no difference in any of the secondary outcomes (percentage of valid data points, percentage of time saturation below target, and so on) between the two groups in both pulse oximeters. Masimo sensor readings displayed a higher mean oxygen saturation (mean difference of 2.85, p=0.001) and lower percentage of time saturation below 94% (mean difference of −27.8, p=0.001) than Nellcor in both groups. There was no difference in any of the outcomes in babies receiving phototherapy (n=21). Conclusion: In this study, shielding the pulse oximeter sensor from ambient light or phototherapy light did not yield faster data acquisition or better data quality. Trial registration number: ISRCTN10302534 … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 106:Issue 1(2021)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 106:Issue 1(2021)
- Issue Display:
- Volume 106, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 106
- Issue:
- 1
- Issue Sort Value:
- 2021-0106-0001-0000
- Page Start:
- 57
- Page End:
- 61
- Publication Date:
- 2020-07-01
- Subjects:
- neonatology -- monitoring -- technology
Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2020-319049 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17204.xml