Mobile, Remote, and Individual Focused: Comparing Breath Carbon Monoxide Readings and Abstinence Between Smartphone-Enabled and Stand-Alone Monitors. Issue 4 (6th October 2020)
- Record Type:
- Journal Article
- Title:
- Mobile, Remote, and Individual Focused: Comparing Breath Carbon Monoxide Readings and Abstinence Between Smartphone-Enabled and Stand-Alone Monitors. Issue 4 (6th October 2020)
- Main Title:
- Mobile, Remote, and Individual Focused: Comparing Breath Carbon Monoxide Readings and Abstinence Between Smartphone-Enabled and Stand-Alone Monitors
- Authors:
- Tuck, Breanna M
Karelitz, Joshua L
Tomko, Rachel L
Dahne, Jennifer
Cato, Patrick
McClure, Erin A - Abstract:
- Abstract: Introduction: Newly available, smartphone-enabled carbon monoxide (CO) monitors are lower in cost than traditional stand-alone monitors and represent a marked advancement for smoking research. New products are promising, but data are needed to compare breath CO readings between smartphone-enabled and stand-alone monitors. The purpose of this study was to (1) determine the agreement between the mobile iCO (Bedfont Scientific Ltd) with two other monitors from the same manufacturer (Micro + pro and Micro + basic) and (2) determine optimal, monitor-specific, cotinine-confirmed abstinence cutoff values. Methods: Adult (≥18) smokers ( n = 26) and nonsmokers ( n = 21) provided three breath CO samples (using three different monitors) in each of 10 sessions, and urine cotinine was measured for gold standard determination of abstinence. CO comparisons ( N = 437) were analyzed using regression-based Bland–Altman Analysis of Agreement; receiver operating characteristics curves were used to determine optimal abstinence cutoffs. Results: Bland–Altman analyses indicated that the iCO monitor provided higher CO results than both Micro + monitors. Sensitivity and specificity analyses showed that the optimal CO cutoff for determining abstinence was <3 ppm for the Micro + pro (88% sensitivity, 93% specificity) and Micro + basic (83% sensitivity, 98% specificity), but was higher for the iCO (<6 ppm; 73% sensitivity, 100% specificity). Conclusions: Relative to both Micro + monitors, theAbstract: Introduction: Newly available, smartphone-enabled carbon monoxide (CO) monitors are lower in cost than traditional stand-alone monitors and represent a marked advancement for smoking research. New products are promising, but data are needed to compare breath CO readings between smartphone-enabled and stand-alone monitors. The purpose of this study was to (1) determine the agreement between the mobile iCO (Bedfont Scientific Ltd) with two other monitors from the same manufacturer (Micro + pro and Micro + basic) and (2) determine optimal, monitor-specific, cotinine-confirmed abstinence cutoff values. Methods: Adult (≥18) smokers ( n = 26) and nonsmokers ( n = 21) provided three breath CO samples (using three different monitors) in each of 10 sessions, and urine cotinine was measured for gold standard determination of abstinence. CO comparisons ( N = 437) were analyzed using regression-based Bland–Altman Analysis of Agreement; receiver operating characteristics curves were used to determine optimal abstinence cutoffs. Results: Bland–Altman analyses indicated that the iCO monitor provided higher CO results than both Micro + monitors. Sensitivity and specificity analyses showed that the optimal CO cutoff for determining abstinence was <3 ppm for the Micro + pro (88% sensitivity, 93% specificity) and Micro + basic (83% sensitivity, 98% specificity), but was higher for the iCO (<6 ppm; 73% sensitivity, 100% specificity). Conclusions: Relative to both Micro + monitors, the smartphone-enabled iCO provided systematically higher CO values and required a higher cutoff to reliably determine smoking abstinence. This does not indicate that CO values obtained using the iCO are not valid; instead, these results suggest that monitor-specific abstinence cutoffs are needed to ensure accurate bioverification of smoking status. Implications: Results from this study indicate that CO values from the smartphone-enabled iCO should not be used interchangeably with the stand-alone Micro + pro and Micro + basic, particularly when lower CO values (<10 ppm) are critical (ie, determination of abstinence vs confirming smoking status for study inclusion). Optimal CO cutoffs recommended for determining abstinence on Micro + and iCO monitors are at <3 and <6 ppm, respectively. … (more)
- Is Part Of:
- Nicotine & tobacco research. Volume 23:Issue 4(2021)
- Journal:
- Nicotine & tobacco research
- Issue:
- Volume 23:Issue 4(2021)
- Issue Display:
- Volume 23, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 4
- Issue Sort Value:
- 2021-0023-0004-0000
- Page Start:
- 741
- Page End:
- 747
- Publication Date:
- 2020-10-06
- Subjects:
- Nicotine -- Periodicals
Tobacco -- Research -- Periodicals
Tobacco habit -- Periodicals
Nicotine -- Periodicals
Tobacco -- Periodicals
Smoking -- Periodicals
613.85 - Journal URLs:
- http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=94a708f2c2dd42cb9f0841fff9268622&referrer=parent&backto=searchpublicationsresults, 1, 1;homemain, 1, 1; ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ntr/ntaa203 ↗
- Languages:
- English
- ISSNs:
- 1462-2203
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6110.106500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17145.xml