Different tissue thermodynamics between the 40 W and 20 W radiofrequency power settings under the same ablation index/lesion size index. (2nd December 2019)
- Record Type:
- Journal Article
- Title:
- Different tissue thermodynamics between the 40 W and 20 W radiofrequency power settings under the same ablation index/lesion size index. (2nd December 2019)
- Main Title:
- Different tissue thermodynamics between the 40 W and 20 W radiofrequency power settings under the same ablation index/lesion size index
- Authors:
- Takemoto, Makoto
Takami, Mitsuru
Fukuzawa, Koji
Kiuchi, Kunihiko
Kurose, Jun
Suehiro, Hideya
Nagamatsu, Yuichi
Akita, Tomomi
Nakamura, Toshihiro
Sakai, Jun
Yatomi, Atsusuke
Hirata, Ken‐ichi - Abstract:
- Abstract: Introduction: The ablation index (AI) and lesion size index (LSI) are novel markers for predicting the ablation lesion quality, however, collateral damage is still a concern. This study aimed to compare the lesion characteristics and tissue temperature profiles between 20 W (20 Ws) and 40 W (40 Ws) ablation settings under the same AI and LSI. Methods: An ex vivo model consisting of swine myocardium (5‐6 mm thickness) in a circulating, warmed saline bath was used. Twenty‐one tissue temperature electrodes were used. Radiofrequency applications with different power settings were performed with a 10 to 12 g contact force until the AI and LSI reached 350 and 4.5, respectively. Results: A total of 120 radiofrequency (RF) applications and 2520 tissue temperature profiles were analyzed. The speed of the tissue temperature rise with 40 Ws was significantly faster than that with 20 Ws. However, the maximum tissue temperature did not significantly differ between 20 and 40 Ws with the same AI (44.6°C ± 3.9°C vs 45.1°C ± 6.4°C, P = .73), and was significantly lower for 40 Ws with the same LSI (42.8°C ± 3.4°C vs 40.0°C ± 3.4°C, P = .003). For both the AI and LSI, the number of electrodes exhibiting high temperatures (≥39°C) was significantly larger and the duration of high tissue temperatures was significantly longer with 20 Ws. The thermal latency with 40 Ws was greater. Conclusions: Although the targeted AI and LSI were the same for both 20 and 40 Ws, the tissue temperatureAbstract: Introduction: The ablation index (AI) and lesion size index (LSI) are novel markers for predicting the ablation lesion quality, however, collateral damage is still a concern. This study aimed to compare the lesion characteristics and tissue temperature profiles between 20 W (20 Ws) and 40 W (40 Ws) ablation settings under the same AI and LSI. Methods: An ex vivo model consisting of swine myocardium (5‐6 mm thickness) in a circulating, warmed saline bath was used. Twenty‐one tissue temperature electrodes were used. Radiofrequency applications with different power settings were performed with a 10 to 12 g contact force until the AI and LSI reached 350 and 4.5, respectively. Results: A total of 120 radiofrequency (RF) applications and 2520 tissue temperature profiles were analyzed. The speed of the tissue temperature rise with 40 Ws was significantly faster than that with 20 Ws. However, the maximum tissue temperature did not significantly differ between 20 and 40 Ws with the same AI (44.6°C ± 3.9°C vs 45.1°C ± 6.4°C, P = .73), and was significantly lower for 40 Ws with the same LSI (42.8°C ± 3.4°C vs 40.0°C ± 3.4°C, P = .003). For both the AI and LSI, the number of electrodes exhibiting high temperatures (≥39°C) was significantly larger and the duration of high tissue temperatures was significantly longer with 20 Ws. The thermal latency with 40 Ws was greater. Conclusions: Although the targeted AI and LSI were the same for both 20 and 40 Ws, the tissue temperature profiles differed greatly depending on the RF power setting. A high power setting based on the AI and LSI may reduce the collateral thermal damage. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 1(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 1(2020)
- Issue Display:
- Volume 31, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2020-0031-0001-0000
- Page Start:
- 196
- Page End:
- 204
- Publication Date:
- 2019-12-02
- Subjects:
- ablation index -- catheter ablation -- lesion size index -- tissue thermodynamics
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14285 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17177.xml