Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study. Issue 6 (17th February 2019)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study. Issue 6 (17th February 2019)
- Main Title:
- Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study
- Authors:
- Blackman, Daniel J.
Van Gils, Lennart
Bleiziffer, Sabine
Gerckens, Ulrich
Petronio, Anna Sonia
Abdel‐Wahab, Mohamed
Werner, Nikos
Khogali, Saib S.
Wenaweser, Peter
Wöhrle, Jochen
Soliman, Osama
Laborde, Jean‐Claude
Allocco, Dominic J.
Meredith, Ian T.
Falk, Volkmar
Van Mieghem, Nicolas M. - Abstract:
- Abstract: Aims: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post‐market registry. Methods and Results: The prospective, open‐label RESPOND study enrolled 1, 014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve‐in‐valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30‐day follow‐up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge ( P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm 2 to 1.7 ± 0.4 cm 2 ( P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM‐naïve patients was 22.2% (6/27). Conclusions: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspidAbstract: Aims: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post‐market registry. Methods and Results: The prospective, open‐label RESPOND study enrolled 1, 014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve‐in‐valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30‐day follow‐up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge ( P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm 2 to 1.7 ± 0.4 cm 2 ( P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM‐naïve patients was 22.2% (6/27). Conclusions: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 93:Issue 6(2019)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 93:Issue 6(2019)
- Issue Display:
- Volume 93, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 93
- Issue:
- 6
- Issue Sort Value:
- 2019-0093-0006-0000
- Page Start:
- 1116
- Page End:
- 1123
- Publication Date:
- 2019-02-17
- Subjects:
- aortic regurgitation -- aortic valve stenosis -- bicuspid -- transcatheter aortic valve implantation -- transfemoral
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28120 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17151.xml