Arrhythmia‐specific settings for automated high‐density mapping: A multicenter experience. (19th June 2018)
- Record Type:
- Journal Article
- Title:
- Arrhythmia‐specific settings for automated high‐density mapping: A multicenter experience. (19th June 2018)
- Main Title:
- Arrhythmia‐specific settings for automated high‐density mapping: A multicenter experience
- Authors:
- Sommer, Philipp
Albenque, Jean‐Paul
van Driel, Vincent
Pierre, Bertrand
Tondo, Claudio
Roithinger, Franz Xaver
Poty, Hervé
Miller, Amber
Della Bella, Paolo - Abstract:
- Abstract: Background: Advancements in electrophysiology 3‐D mapping systems facilitate the broadening scope of electrophysiology study and catheter ablation to treat complex arrhythmias. While electroanatomical mapping systems have default settings available for a variety of mapping parameters, significant operator customization driven by arrhythmia type and experience can occur. However, multicenter comprehensive reporting of customized mapping settings is lacking. Methods: In this prospective, multicenter observational registry, subjects with cardiac arrhythmias underwent electrophysiology study and ablation procedure using the EnSite Precision™ electroanatomical mapping system per standard of care, and associated automated mapping thresholds and procedural characteristics were observed. Results: Cardiac mapping and ablation was performed in 503 patients (64.4% male, 59.6 ± 13.2 years) for a variety of indications including atrial fibrillation (N = 277), atrial flutter (N = 67), other supraventricular tachycardias (N = 96), and ventricular tachycardia (N = 56). Automated electroanatomical mapping was used to generate 88.2% of all maps, and arrhythmia‐specific adjustments of mapping thresholds were utilized to collect electrophysiologically relevant data. The most commonly used thresholds for mapping in AF were Distance (average 2.7 ± 3.5 mm) and Signal‐to‐Noise Ratio (5.2 ± 1.1), while mapping in VT commonly used Score (88.5 ± 6.5%) and Distance (0.6 ± 0.5 mm). AutomatedAbstract: Background: Advancements in electrophysiology 3‐D mapping systems facilitate the broadening scope of electrophysiology study and catheter ablation to treat complex arrhythmias. While electroanatomical mapping systems have default settings available for a variety of mapping parameters, significant operator customization driven by arrhythmia type and experience can occur. However, multicenter comprehensive reporting of customized mapping settings is lacking. Methods: In this prospective, multicenter observational registry, subjects with cardiac arrhythmias underwent electrophysiology study and ablation procedure using the EnSite Precision™ electroanatomical mapping system per standard of care, and associated automated mapping thresholds and procedural characteristics were observed. Results: Cardiac mapping and ablation was performed in 503 patients (64.4% male, 59.6 ± 13.2 years) for a variety of indications including atrial fibrillation (N = 277), atrial flutter (N = 67), other supraventricular tachycardias (N = 96), and ventricular tachycardia (N = 56). Automated electroanatomical mapping was used to generate 88.2% of all maps, and arrhythmia‐specific adjustments of mapping thresholds were utilized to collect electrophysiologically relevant data. The most commonly used thresholds for mapping in AF were Distance (average 2.7 ± 3.5 mm) and Signal‐to‐Noise Ratio (5.2 ± 1.1), while mapping in VT commonly used Score (88.5 ± 6.5%) and Distance (0.6 ± 0.5 mm). Automated mapping collected and utilized 8.8 times more data than manual mapping without increasing mapping time. Conclusions: This registry revealed arrhythmia‐specific automated mapping settings used to generate electroanatomical maps of multiple cardiac rhythms with higher point density than manual mapping without increasing mapping time. Commonly used mapping threshold settings could serve as an important reference for new automated electroanatomical mapping users or those expanding their usage to new indications and arrhythmias. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 29:Number 9(2018)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 29:Number 9(2018)
- Issue Display:
- Volume 29, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 9
- Issue Sort Value:
- 2018-0029-0009-0000
- Page Start:
- 1210
- Page End:
- 1220
- Publication Date:
- 2018-06-19
- Subjects:
- atrial fibrillation -- atrial flutter -- catheter ablation -- electroanatomical mapping -- Ensite Precision™ -- ventricular tachycardia
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13649 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17153.xml