Diagnostic accuracy of clinical tests for cam or pincer morphology in individuals with suspected FAI syndrome: a systematic review. Issue 1 (27th April 2020)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of clinical tests for cam or pincer morphology in individuals with suspected FAI syndrome: a systematic review. Issue 1 (27th April 2020)
- Main Title:
- Diagnostic accuracy of clinical tests for cam or pincer morphology in individuals with suspected FAI syndrome: a systematic review
- Authors:
- Caliesch, Rahel
Sattelmayer, Martin
Reichenbach, Stephan
Zwahlen, Marcel
Hilfiker, Roger - Abstract:
- Abstract : Objectives: To determine the diagnostic accuracy of clinical tests for cam or pincer morphology in individuals with suspected femoroacetabular impingement (FAI) syndrome and to evaluate their clinical utility. Design: A systematic review of studies investigating the diagnostic accuracy of clinical tests for cam and pincer morphology. Data sources: PubMed, Embase, CINAHL and SPORTDiscus. Eligibility criteria for selecting studies: Studies investigating the diagnostic accuracy of clinical tests for cam, pincer or mixed morphology in symptomatic patients. Patients had to undergo an index test and a reference test able to identify cam or pincer morphology. Study results have to allow the calculation of true or false positives and/or negatives to calculate sensitivity, specificity, likelihood ratios (LR) and post-test probabilities. Results: Eight studies were included, investigating 17 tests and two test combinations. The studies reported a low specificity for all tests, ranging from 0.11 to 0.56. Sensitivity ranged from 0.11 to 1.00, with high sensitivities for the flexion-adduction-internal rotation (FADIR), foot progression angle walking (FPAW) and maximal squat tests. We estimated that negative test results on all of these three tests would result in a negative LR of 0.15. However, we judged the studies to provide low-quality evidence. Conclusion: There is low-quality evidence that negative test results reduce the post-test probability of cam or mixed morphologiesAbstract : Objectives: To determine the diagnostic accuracy of clinical tests for cam or pincer morphology in individuals with suspected femoroacetabular impingement (FAI) syndrome and to evaluate their clinical utility. Design: A systematic review of studies investigating the diagnostic accuracy of clinical tests for cam and pincer morphology. Data sources: PubMed, Embase, CINAHL and SPORTDiscus. Eligibility criteria for selecting studies: Studies investigating the diagnostic accuracy of clinical tests for cam, pincer or mixed morphology in symptomatic patients. Patients had to undergo an index test and a reference test able to identify cam or pincer morphology. Study results have to allow the calculation of true or false positives and/or negatives to calculate sensitivity, specificity, likelihood ratios (LR) and post-test probabilities. Results: Eight studies were included, investigating 17 tests and two test combinations. The studies reported a low specificity for all tests, ranging from 0.11 to 0.56. Sensitivity ranged from 0.11 to 1.00, with high sensitivities for the flexion-adduction-internal rotation (FADIR), foot progression angle walking (FPAW) and maximal squat tests. We estimated that negative test results on all of these three tests would result in a negative LR of 0.15. However, we judged the studies to provide low-quality evidence. Conclusion: There is low-quality evidence that negative test results reduce the post-test probability of cam or mixed morphologies and that consecutive testing with the FADIR, FPAW and maximal squat tests might be used as a clinical test combination. We would not recommend their use to confirm the diagnosis of FAI syndrome. PROSPERO registration number: CRD42018079116. … (more)
- Is Part Of:
- BMJ open sport & exercise medicine. Volume 6:Issue 1(2020)
- Journal:
- BMJ open sport & exercise medicine
- Issue:
- Volume 6:Issue 1(2020)
- Issue Display:
- Volume 6, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 6
- Issue:
- 1
- Issue Sort Value:
- 2020-0006-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04-27
- Subjects:
- hip -- review -- sports physiotherapy -- validity
Sports medicine -- Periodicals
Exercise therapy -- Periodicals
617.102705 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopensem.bmj.com/ ↗ - DOI:
- 10.1136/bmjsem-2020-000772 ↗
- Languages:
- English
- ISSNs:
- 2055-7647
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17132.xml